background image

5.1.1. EXAMPLE OF CONNECTION SENSORS TO ADA-401WP

6

DES-300E

T

x-

/B

T

x+

/A

R

x-

C

o

m

p

u

te

w

ith

F

re

e

 S

C

A

D

A

or

P

LC

 w

ith

 s

up

p

or

t M

O

D

B

U

S

 

p

ro

to

co

l

P

ow

er

 s

up

pl

y

12

 V

D

C

1-W

IR

E

RS

485

MO

DB

US

A

D

A

-I

10

40

A

D

A

I9

14

0

D

E

S

-3

00

E

-T

G

N

D

R

x+

1-

W

V

D

D

R

S

23

2

U

S

B

RS

485

MO

DB

US

P

E

 

G

N

D

T

x-

/B

T

x+

/A

R

x-

G

N

D

R

x+

RS

232

US

B

V

ss

V

ss

+

 

U

nu

se

d

 tw

is

te

p

a

ir 

ca

b

le

a

re

 c

o

n

ne

ct

e

d

 to

g

et

h

e

an

d

 

co

n

ne

ct

e

d

 to

 P

E

 e

le

ct

ri

ca

l w

ir

in

g

.

230V~

V

N

 

V

+

 

12V=

 

A

D

A

-4

01

W

P

D

E

S

-3

00

E

-T

-H

D

E

S

-3

00

E

-T

-H

R

S

48

5(

2W

)

U

to

 1

20

0m

C

a

bl

e

 U

T

P

 4

x2

x0

,5

GND

NC

VD

D

+12

V

1-W

GN

D

NC

VDD

+12

V

1-W

GN

D

NC

VDD

+12

V

1-W

Содержание DES-300E

Страница 1: ...User manual DES 300E Digital environmental parameters sensor 1 io_des 300e_v1 00_en DES 300E Copyright 2001 2017 CEL MAR sp j...

Страница 2: ...2 APPLICATION 3 3 COOPERATION WITH OTHER 1 WIRE DEVICES 4 4 VIEW OF SENSOR 4 5 CONNECTION OF 1 WIRE BUS 5 5 1 CONNECTION TO 1 WIRE BUS SENSOR POWER SUPPLY FROM ADA 401WP 5 5 1 1 EXAMPLE OF CONNECTION...

Страница 3: ...merse device in water or no other liquid Do not put the fire opened on device sources candles an oil lamps and the like 1 3 CE LABEL CE symbol on organizing the company CEL MAR a conformity of the dev...

Страница 4: ...toring and control systems for environmental parameters ADA 401WP Measuring Module 1 WIRE to MODBUS RTU DNB 400 Passive 1 WIRE Bus Splitter DNB 215 Passive 1 WIRE Bus Splitter DNB 200 Passive 1 WIRE B...

Страница 5: ...nect the bus to terminal block described as below 5V powering the bus 5VDC 1 W 1 WIRE data transmission GND signal ground b after connection 1 WIRE bus to terminals 5V 1 W GND of DES 300E set the S1 s...

Страница 6: ...S485 MODBUS ADA I1040 ADAI9140 DES 300E T GND Rx 1 W VDD L RS232 USB RS485 MODBUS PE GND Tx B Tx A Rx GND Rx RS232 USB Vss Vss Unused twisted pair cables are connected together and connected to PE ele...

Страница 7: ...owering from additional power supply 1 W data transmission 1 WIRE GND signal ground b after connection 1 WIRE bus to terminals 12VDC 1 W GND of DES 300E set the S1 switch to 12V position Not applicabl...

Страница 8: ...S PE GND Tx B Tx A Rx GND Rx RS232 USB Vss Vss 230V V N V 12V ADA 401WP DES 300E T H DES 300E T H GND NC VDD 12V 1 W GND NC VDD 12V 1 W GND NC VDD 12V 1 W Computer with Free SCADA or PLC with support...

Страница 9: ...s 0 06 C Parameters of Humidity Sensor Measuring range of relative humidity 0 100 RH Measuring accuracy of relative humidity 3 50 RH Parameters of Lighting Sensor Measuring range of lighting 0 100 Lux...

Страница 10: ...10 DES 300E...

Страница 11: ...11 DES 300E...

Страница 12: ...c Converters 1 Wire ETHERNET Wi Fi digital sensors as temperature humidity pressure illumination power supply Please express your opinion by e mail or phone on this product and advise us how we can sa...

Отзывы: