background image

2.2. DESCRIPTION

ADA-I9141 converts 

USB to RS-485/RS-422 standard  without interference of data format and it is automatically detect by PC system

after connecting to USB network (Plug&Play device).  ADA-I9141 uses data transmission lines Rx, Tx & GND (signal ground) for

communication with other RS485/422 devices.

This converter doesn't required  external power supply (it is powered from USB bus) and it uses asynchronous baud rate up to 921,3

kbps (drivers for STANDARD baud rate) / 1500000 bps (drivers for PROFIBUS baud rate). 

A-type  USB  Mail   plug   (or  USB  cable   with   A-type   connector)   enables   simple   connection  to   computer  and   on   other  side  simple

connection the RS485/422 Bus provide plug-in screw terminal block.

Together with the ADA-I9141 we provide the drivers, which after installation, create in operating system additional COM port on the

next free number e.g. COM3. It can be use as standard COM port but it isn't hardware port but virtual, create in Windows system. This

is the reason why some applications running in DOS and use this port, can operate improperly.

3. CONFIGURATION 

ADA-I9141 converter can be configured for operating in RS485 or RS422 by the use MODE switch (fig.1). Description of setting is

shown in the table below.

Switch

MODE

Description

RS485

Operating in RS485 standard on 2 and 4-wire bus in point-to-point or multi-point topology. 

RS485 transmitter enable only during data transmission

RS422

Operating in RS422 standard on 4-wire bus in point-to-point. 

RS422 transmitter continuously enable.

Fig 1. ADA-I9141 view

4. INSTALLATION

This chapter will show you correctly connection of the ADA-I9141 to RS-485/RS-422 Bus. To compensate the ground potential of

devices operating on RS485/RS422 Bus you should connect the grounds of RS485/RS422 interfaces to the converter terminals GND.

This connection should be done individually for each systems if standard wiring of RS485/RS422 bus not provide correct transmission.
In the purpose of disruptions minimization of  influence from environment you should :

- use shielded twisted-pair cable in the system, of which it is possible to connect the shield to ground on one end of cable,

- lay the signals cable in the distance no short than with 25 cm from power cable.

4.1. CONNECTION TO RS485/RS422 BUS

RS485/RS422 interface of ADA-I9141 converter is available on screw terminal block described as: Tx+/A, Tx-/B, Rx+, Rx-, GND.

ADA-I9141 can operate on RS422 bus or RS485 bus - both bus need suitable wiring.

4.1.1. CONNECTION TO  RS422 OR RS485 (4W) BUS 4-WIRE 

Examples connection of ADA-I9141 to RS422 4-wire bus or RS485(4W) in point-to-point and multi-point topology are shown below.

4

ADA-I9141

TX

RX

485

422

MODE

ADA-I9141

TX+/ A

TX-/ B

RX+

RX-

GND

®

77mm

68mm

31

m

m

24

,5

m

m

TX-
RX+
RX-
GND

DATA+ / A
DATA- / B

TX+

RS-485

2-WIRE

RS-485 

4-WIRE

 or

RS-422

Содержание ADA-I9141

Страница 1: ...User manual ADA I9141 USB to RS 485 RS 422 converter without galvanic isolation 1 io_ada i9141_en_v3 13 ADA I9141 Copyright 2001 2017 CEL MAR sp j...

Страница 2: ...INTERFACE OF PC 6 4 4 POWER SUPPLY 6 5 DRIVERS INSTALLATION IN SYSTEM WINDOWS 6 5 1 EXAMPLE DRIVER INSTALLATION IN WINDOWS 7 SYSTEM 6 6 DRIVER UNINSTALLATION 12 6 1 DRIVER UNINSTALLATION IN WINDOWS 9...

Страница 3: ...ire opened on device sources candles an oil lamps and the like Complete disable from the supply network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or di...

Страница 4: ...n 2 and 4 wire bus in point to point or multi point topology RS485 transmitter enable only during data transmission RS422 Operating in RS422 standard on 4 wire bus in point to point RS422 transmitter...

Страница 5: ...cal reflection in data line at high baud rate It is not needed below 9600Bd You should use the Line Termination resistor if the distance is over 1000m 9600Bd or 700m 19200Bd transmission The Line Term...

Страница 6: ...f installation wizard will be installed the Drivers and Uninstaller for the Windows systems 98 ME 2000 XP 2003 Vista Win7 2008 d connect the convert to USB port of computer and follow the steps of ins...

Страница 7: ...Select STANDARD Drivers and press Next Press Install 7 ADA I9141...

Страница 8: ...Press Next will be installed Drivers for USB Bus 8 ADA I9141...

Страница 9: ...Press Install this driver software anyway Installation of drivers for USB Bus will start 9 ADA I9141...

Страница 10: ...Press Install this driver software anyway Installation of drivers for Virtual Port will start Press Finish 10 ADA I9141...

Страница 11: ...Press Finish The driver for ADA I9141 have been installed This can be checked in Uninstall or change a program Now you can connect ADA I9141 to computer port 11 ADA I9141...

Страница 12: ...a disconnect converter from computer b select menu Start Setting Control Panel Add Remove Programs c select from the list ADA USB Serial Converter Driver and press Change Remove e reboot the computer...

Страница 13: ...ME 2000 system have to be done according follow steps a disconnect converter from computer b from CD ROM delivered with converter copy to hard disk the folder Windows Win 98ME_1 09 06 FTClean for Wind...

Страница 14: ...pe Mail Screw terminal block max wire 1mm2 Line length up to 5m 1200 m depend on baud rate Max number of connected devices 1 32 2 Transmission line USB cable with socked A type Twisted cable 1 pair 2...

Страница 15: ...nsions W x D x H 55mm x 30mm x 24 5mm Material ABS Degree of casing protection IP30 Weight 0 10 kg Implementation of Standard Not applicable Location during work Free Mounting method Not applicable 15...

Страница 16: ...orld in applications such as data transmission converters in RS232 RS485 RS422 USB Current Loop Fibre Optic and Ethernet Converters and many others We welcome your feedback so please contact us to tel...

Отзывы: