1. GENERAL INFORMATION

Thank you for your purchase of 

CEL-MAR Company

 product. This product has been completely tested and is covered by a two year

warranty on parts and operation from date of sale.

If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48

41 362-12-46 or e-mail [email protected].

1.1. WARRANTED INFORMATION 

The  

ADA-I9141  

converter is covered by a two year warranty from date of sale.   In case of being damaged it will be repair or the

damaged component will be replace. The warranty does not cover damage caused from improper use, materials consumption or any

unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be

repaired.
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases

 CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged  so

as not to be exposed to trampling, attaching, or pulling out of the circuit. 

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

Complete disable from the supply network is only after disconnecting the power supply circuit voltage. 

Do not carry out the assembly or disassembly of the device if it is enabled. This may result to short circuit and damage the device.

The device can not be used for applications that determine human life and health (eg. Medical). 

1.3. CE LABEL

The   CE   symbol   on   the   device   CEL-MAR   means   compatibility   with   electromagnetic   compatibility   Electromagnetic
Compatibility   Directive  

EMC   2014/30/WE.

  Declaration   of   Conformity  is   available   by   contact   with   Technical   Service

(email: [email protected]; phone: +48 41 362-12-46).

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND MAINTENANCE

The 

ADA-I9141 converter 

does not require the servicing and maintenance.

Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail 

[email protected]

.

1.6. PACK CONTENTS

The converter is delivered with the user manual and CD-ROM with software.

2. PRODUCT INFORMATION

2.1. PROPERTIES

Conversion of USB to RS485/422 standard,

Compatibility with USB1.1 and USB 2.0 standard,

Virtual Serial Port,

Transmitted signals: RX, TX,

Operate on the Bus: RS485 two-wire and four-wire in point-to-point mode or multi-point, RS422 in point-to-point mode,

STANDARD Baud rate (bps): 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600,

PROFIBUS baud rate ( bps): 300 bps, 600 bps, 1200 bps, 2400 bps, 4800 bps, 9600 bps,19200 bps, 

93750

(230400) bps, 

187500

(460800) bps, 

500000

(921600) bps, 

1500000

(14400) bps.

Transparent for all protocols:  MODBUS, DNP, PROFIBUS and other,

Any format of byte defined with the specification of RS232 interface,

Power supply from the USB port,

Interface casing,

RS-485/RS-422 interface connection via screw terminal block – max.Ø 1mm² ,

USB interface connection via Mail USB connector A-type or USB cable with A-type connector,

Casing dimensions (W x D x H)  55 mm x 30 mm x 24,5 mm.

3

ADA-I9141

Содержание ADA-I9141

Страница 1: ...User manual ADA I9141 USB to RS 485 RS 422 converter without galvanic isolation 1 io_ada i9141_en_v3 13 ADA I9141 Copyright 2001 2017 CEL MAR sp j...

Страница 2: ...INTERFACE OF PC 6 4 4 POWER SUPPLY 6 5 DRIVERS INSTALLATION IN SYSTEM WINDOWS 6 5 1 EXAMPLE DRIVER INSTALLATION IN WINDOWS 7 SYSTEM 6 6 DRIVER UNINSTALLATION 12 6 1 DRIVER UNINSTALLATION IN WINDOWS 9...

Страница 3: ...ire opened on device sources candles an oil lamps and the like Complete disable from the supply network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or di...

Страница 4: ...n 2 and 4 wire bus in point to point or multi point topology RS485 transmitter enable only during data transmission RS422 Operating in RS422 standard on 4 wire bus in point to point RS422 transmitter...

Страница 5: ...cal reflection in data line at high baud rate It is not needed below 9600Bd You should use the Line Termination resistor if the distance is over 1000m 9600Bd or 700m 19200Bd transmission The Line Term...

Страница 6: ...f installation wizard will be installed the Drivers and Uninstaller for the Windows systems 98 ME 2000 XP 2003 Vista Win7 2008 d connect the convert to USB port of computer and follow the steps of ins...

Страница 7: ...Select STANDARD Drivers and press Next Press Install 7 ADA I9141...

Страница 8: ...Press Next will be installed Drivers for USB Bus 8 ADA I9141...

Страница 9: ...Press Install this driver software anyway Installation of drivers for USB Bus will start 9 ADA I9141...

Страница 10: ...Press Install this driver software anyway Installation of drivers for Virtual Port will start Press Finish 10 ADA I9141...

Страница 11: ...Press Finish The driver for ADA I9141 have been installed This can be checked in Uninstall or change a program Now you can connect ADA I9141 to computer port 11 ADA I9141...

Страница 12: ...a disconnect converter from computer b select menu Start Setting Control Panel Add Remove Programs c select from the list ADA USB Serial Converter Driver and press Change Remove e reboot the computer...

Страница 13: ...ME 2000 system have to be done according follow steps a disconnect converter from computer b from CD ROM delivered with converter copy to hard disk the folder Windows Win 98ME_1 09 06 FTClean for Wind...

Страница 14: ...pe Mail Screw terminal block max wire 1mm2 Line length up to 5m 1200 m depend on baud rate Max number of connected devices 1 32 2 Transmission line USB cable with socked A type Twisted cable 1 pair 2...

Страница 15: ...nsions W x D x H 55mm x 30mm x 24 5mm Material ABS Degree of casing protection IP30 Weight 0 10 kg Implementation of Standard Not applicable Location during work Free Mounting method Not applicable 15...

Страница 16: ...orld in applications such as data transmission converters in RS232 RS485 RS422 USB Current Loop Fibre Optic and Ethernet Converters and many others We welcome your feedback so please contact us to tel...

Отзывы: