9. VERSIONS
ADA-4040PC8 -
-
Order example:
Product Symbol:
ADA-4040PC8-1-23
1
– standard version ,
23
- 1 kV =, 3-way galvanic isolation,
Version:
Standard
1
3-way galvanic isolation:
1 kV =
23
3 kV =
33
10. SPECIFICATION
TECHNICAL DATE
Transition Parameters
Protocol
VIRAP* JCT-ASCII
MODBUS-RTU
Interface
RS-485 / RS-422 (JCT)
RS-485 / RS-422 (RTU)
Connector
Screw terminal, wire max. Ø 2.5 mm2
Screw terminal, wire max. Ø 2.5 mm2
Line length
1200 m (depends he baud rate)
1200 m (depends he baud rate)
Max. number of connected device
1 device
Up it 32 devices
Baud rates (bps)
300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600, 76800,
115200, 230400,
Date formats
Date bits 5, 6, 7, 8, Parity: None, Parity, Odd, Number of melt bits: 1, 2,
Transmission line
Twisted cable 1-pair or 2-pair, UTP Nx2x0, 5 (24 AWG), shield inside large interferences STP
Nx2x0, 5 (24 AWG).
Transmission type
Asynchronism maximum duplex, half duplex.
Standards
EIA-485, CCITT V. 11
EIA-485, CCITT V. 11
Optical signalisation
•
PWR - green LED power supply, RX - of LED roadsteads receiving date from RTU of ports -
RS485 / RS422, TX - yellow LED date transmission through RTU of ports - RS485 / RS422.
Electrical Parameters
Power requirements
10 - 24 - 30 V DC
Power Cable
Recommended length of power cable - up it is 3m.
Power
< 2 W
Protection from reverse power
polarization
YES
Galvanic Isolation
1 kVDC or 3 kVDC - between power circuit and signal lines RS-485 / RS-422 JCT and RTU -
depend the version.
Optoisolation
~ 3 kV - between signal line RS-485 / RS-422 (JCT) and RS-485 / RS-422 (RTU)
Electromagnetic compatibility
Resistance it disruptions according it the standard PN-EN 55024. Emission of disruptions
according it the standard PN-EN 55022.
Safety requiring
According it the PN-EN 60950 norms.
Environment
Commercial and light industrial.
Environmental Parameters
Operating temperature
-30 ÷ 60 ° C
Humidity
5 ÷ of the 95% - non-condensing
Storage temperature
-40 ÷ 70 ° C
Casing
Dimensions
53 x 90 x 62 mm
Material
PC/ABS
Degree of casing protection
IP40
Degree of terminal protection
IP20
Weight
0.10 kg
According is a standard
DIN EN50022, DIN EN43880
Position during operation
Free
Mounting
Rail mounting according it is DIN35 standard / TS35.
*) - Names of companies and logotypes have been used only for informational purposes
16
ADA-4040PC8