1. GENERAL INFORMATION

Thank you for your purchase of 

CEL-MAR Company

 product. This product has been completely tested and is covered by a two year

warranty on parts and operation from date of sale. 

If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48

41 362-12-46 or e-mail [email protected].

1.1. WARRANTED INFORMATION 

ADA-4040A 

converter is covered by a two year warranty from date of sale.  In case of being damaged it will be repair or the damaged

component   will   be   replace.  The   warranty   does   not   cover   damage   caused   from   improper   use,   materials   consumption  or   any

unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be

repaired or replaced.
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases

 CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged  so

as not to be exposed to trampling, attaching, or pulling out of the circuit. 

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

Complete disable from the supply network is only after disconnecting the power supply circuit voltage. 

Do not carry out the assembly or disassembly of the device if it is enabled. This may result to short circuit and damage the device.

The device can not be used for applications that determine human life and health (eg. Medical). 

1.3. CE LABEL

The   CE   symbol   on   the   device   CEL-MAR   means   compatibility   with   electromagnetic   compatibility   Electromagnetic
Compatibility   Directive  

EMC   2014/30/WE.

  Declaration   of   Conformity  is   available   by   contact   with   Technical   Service

(email: [email protected]; phone: +48 41 362-12-46).

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND MAINTENANCE

ADA-4040A converter does not require the servicing and maintenance.

Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail 

[email protected]

.

1.6. PACK CONTENTS

Converter is delivered with: User Manual, Line terminators Rt=120

W

,(4 pcs.), CD with ADAConfig software.

2. PRODUCT INFORMATION

2.1. PROPERTIES

Possibility of adding address to no-addressable device with RS485/422 interface,

Baud rate and format data frame conversion between RS1 and RS2 ports,

Possibility of connection RS-422 interface device to RS-485 network without any interference,

Operating on 2-wire or 4-wire network in RS485/RS422 standard,

Operating up to 32 devices on RS485 bus,

Baud rate (bps) of RS485/422 interfaces: 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600, 

76800, 115200, 230400,

Data format RS485/422: data bit: 5, 6, 7, 8; parity: None, Odd, Even; number of stop bits: 1, 2,

Transparent for all protocols, which data format is compatible with the above specifications of RS485/422 interface eg. MODBUS, 

DNP, PROFIBUS and other,

Power supply 10 - 30 VDC stable min. 2W,

~3kV= optoizolation in signal channel between RS485/RS422 (RS1) and RS485/RS422 (RS2) interface,

1kV= or 3kV= galvanic isolation between RS485/RS422 (RS1, RS2) interfaces and power supply (depend on version),

Connection RS485/RS422 network and power supply via screw terminal block,

Implemented short circuit protection and over-voltage protection on RS485 / RS422 network,

Implemented protection against power supply reverse connection,

3

ADA-4040A

Содержание ADA-4040A

Страница 1: ...User manual ADA 4040A Addressable RS485 RS422 Baud Rate Converter 1 io_ada 4040a_v4 02_en ADA 4040A Copyright 2001 2017 CEL MAR sp j ...

Страница 2: ...CTION 7 3 3 4 LINE TERMINATION 7 3 3 5 SLAVE DEVICE CONNECTION 7 3 4 CONNECTION OF POWER SUPPLY 7 4 ACTIVATION 8 4 1 SIGNALLING LEDS 8 4 2 TROUBLESHOOTING 8 5 CONFIGURATION 8 5 1 OPERATION MODE 8 5 2 CONFIGURATION BY THE USE OF ADACONFIG 8 5 2 1 CONFIGURATION OF ADDRESSING MODE 9 5 2 2 CONFIGURATION OF BAUD RATE AND DATA FORMAT 9 5 2 3 CONFIGURATION DATA FLOW CONTROL 9 5 3 FIRMWARE UPDATE 10 5 4 E...

Страница 3: ...r supply circuit voltage Do not carry out the assembly or disassembly of the device if it is enabled This may result to short circuit and damage the device The device can not be used for applications that determine human life and health eg Medical 1 3 CE LABEL The CE symbol on the device CEL MAR means compatibility with electromagnetic compatibility Electromagnetic Compatibility Directive EMC 2014...

Страница 4: ...on between next segments about the length up to 1200m The converter s galvanic separation protect system constructed on RS 485 RS 422 network and increase functioning reliability ADA 4040A supports an asynchronous baud rate up to 230 4 kbps through four or two pairs of twisted pair cables connected to screw terminals The converter use RX RX TX A TX B lines for functioning It is possible to connect...

Страница 5: ...he cover then press bottom part to hear characteristic Click sound 3 2 COMPUTER CONNECTION To connect ADA 4040A converter via the RS1 port to computer equipped with RS 232 or USB interface is needed additional converter e g ADA I1040 RS232 to RS485 RS422 converter or ADA I9140 USB to RS485 RS422 converter or other which is connected to RS2 port of ADA 4040A The ways of connections of ADA 4040A to ...

Страница 6: ...B GND Rx Rx RS2 screw connector RS485 RS422 ADA 4040A 5 GND GND 2 Rx 3 Tx RS232 connector DB 9F DCE Screw connector RS485 RS422 RS485 4W bus 9600Bd 8 O 1 RS232 connector DB 9M DTE PC or MASTER device ADA I1040 GND 5 Tx 2 Rx 3 Rt Rt Rx Rx Tx A Tx B RS485 2W Tx A Tx B GND Rx Rx Screw connector RS485 RS422 SLAVE 2400Bd 8 N 2 Tx A Tx B GND Rx Rx Screw connector RS485 RS422 SLAVE 19200 Bd 7 N 2 Tx A Tx...

Страница 7: ...verter should be done by the use of DC power supplies regulated output voltage from 10 V to 30V min nominal power 2W e g ZS 12 250 or DR 15 24 Power cable from DC power supplies to device can not be longer than 3m Should be connected positive end of DC power supplies to Vss device terminal and negative end to Vss on terminal block ADA 4040A has protection against power supply reverse connection If...

Страница 8: ...DA 4040A converter can operates in a few modes run configuration factory default emergency firmware update Those modes can be set by use SW1 located by terminal block RS2 after removing terminal cover marked as SW1 All available adjusting the SW1 switch are shown in table below Operation modes SW1 1 SW1 2 Mode OFF OFF Run ON OFF Configuration OFF ON Factory default Turning OFF and ON the power of ...

Страница 9: ...data bites 5 6 7 8 control parity no control parity control control of none parity number of stop bits 1 2 frame spacing range from 4 to 255 silence time as frame s end 5 2 3 CONFIGURATION DATA FLOW CONTROL In the section Data flow control for RS1 RS2 interfaces can be set signal DE Off RS485 RS422 interface operates only in receiving data mode signal DE Toggle RS485 interface operates in receivin...

Страница 10: ...confirmed by correct message Fig 8 Selection of firmware file During loading software the yellow LED located beside SW1 micro switch will blink showing data flow to ADA 4040A If the software loaded correctly yellow LED will be blink with frequency 1 Hz After that set micro switch SW1 to run mode as shown in the table below SW1 1 SW1 2 OFF OFF Yellow LED will be OFF 5 4 EMERGENCY FIRMWARE UPDATE In...

Страница 11: ...e button Read transmission errors and to delete zeroing of counters in the memory of the converter press Delete transmission errors In case of parity errors or frame errors check ADA 4040A converter s configuration and correctness connection of RS485 network to RS1 port and addressable device to converter s RS2 port When diagnostic is finish set SW1 micro switch to run mode see pt OPERATION MODE 6...

Страница 12: ...S 422 and RS 485 4 wire bus Additionally can be set data flow control for RS1 RS485 RS422 interface and RS2 RS485 RS422 interface according to pt CONFIGURATION BY THE USE OF ADACONFIG Figures below present possibility of using the addressable ADA 4040A baud rate converter Fig 9 Connection of no addressable RS422 devices to RS485 bus Fig 10 Connection of RS485 bus segments with different baud rate ...

Страница 13: ...r without inlets plug in screw terminal block 3 9 SPECIFICATION TECHNICAL DATA Transition Parameters Interface RS 485 RS 422 RS1 RS 485 RS 422 RS2 Connector Screw terminal block max Ø 2 5mm2 Screw terminal block max Ø 2 5mm2 Line length 1200 m depend on baud rate 1200 m depend on baud rate Max number of connected device 32 Baud rates 300 600 1200 1800 2400 4800 7200 9600 14400 19200 28800 38400 57...

Страница 14: ... to the PN EN60950 norm Environment Commercial and light industrial Environmental Parameters Operating temperature 30 60 C Humidity 5 95 non condensing Storage temperature 40 70 C Casing Dimensions 53 x 90 x 62 mm Material Noryl UL 94 V O Degree of casing protection IP40 Degree of terminal protection IP20 Weight 0 10 kg According to standards DIN EN50022 DIN EN43880 Location during work Free Mount...

Страница 15: ...15 ADA 4040A ...

Страница 16: ... transmission converters with interface RS232 RS485 RS422 USB Ethernet Wi Fi Current Loop Fibre Optic Converters and other Please contact us to tell how you like our products and how we can satisfy you present and future expectation CEL MAR sp j Computers Science and Electronic Factory str Sciegiennego 219C 25 116 Kielce POLAND Tel 48 41 362 12 46 Tel fax 48 41 361 07 70 Web http www cel mar pl Of...

Отзывы: