Fig 6. Sensor connection to ADA-401WP module with (2-wire) 1-WIRE network 

3.4.2. SUPPORTED SENSORS WITH 1-WIRE INTERFACE 

To ADA-401WP module can be connected devices like :

based on circuits: DS1820, DS18S20, DS18B20, DS1822, DS2438Z, DS2401,

temperature sensors DTS-103 & DTS107,

environmental parameter sensor DES-200 (temperature, relative humidity, atmospheric pressure),

environmental parameter sensor DES-216 (temperature, relative humidity, atmospheric pressure, lighting),

environmental parameter sensor DES-300 (temperature, relative humidity, atmospheric pressure, lighting, sunlight, CO2 

concentration),

PT100 sensor to 1-WIRE converter DES-216-PT100,

PT500 sensor to 1-WIRE converter DES-216-PT500,

PT1000 sensor to 1-WIRE converter DES-216-PT1000,

Analog signal 0-10V DC to 1-WIRE converter DES-216-U,

Analog signal 0-20mA DC to 1-WIRE converter DES-216-I,

Method of connection above sensors to ADA-401WP is shown in user manuals of above devices.

3.4.3. SUPPORTED CIRCUITS WITH 1-WIRE INTERFACE

ADA-401WP module supports 1-WIRE interface circuits like: DS1820, DS18S20, DS18B20, DS1822, DS2438Z, DS2401.

In preparation DS2401 circuit.

3.4.4. 1-WIRE NETWORK LIMITATION

The maximum length of 1-WIRE network as layouts producer can be even 400m and the maximum number of sensors can be 500.

However, when building the network, remember that, each sensor is a shortening of 0,5 meters and 100 meters of cable causes

additional capacity load data line 5nF increasing signal distortion.

The real 1-WIRE network length and number of sensors will be less and will depend on:

type of cables,

topology connections,

quality connections,

interference from external electromagnetic fields.

RECOMMENDATIONS :

using one type of the cable, we recommend computer twisted cables UTP 4x2x0,5, for 1-WIRE bus,

1-WIRE network connection in linear topology or use the passive 1-WIRE network splitter DNB-400,

ending the 1-WIRE network by sensor,

connecting unused wires and screen cable to PE rail of electrical installation.

powering ADA-401WP module from individual power supply.

3.5. POWER SUPPLY CONNECTION

The power supply to ADA-401WP module should be DC (regulated) from 10 V to 30V and minimum nominal power should be 3W,

e.g. ZS-12/250 or DR-15-12. Power cable from DC power supplies to device must not be longer than 3m. 

Observe the polarity, connect positive (+) of DC power supplies to V+ and negative (-) end to V- terminal.  ADA-401WP has the 

protection from opposite connection power supply. If after power, on the front panel is not lit green LED PWR, check the power 

connection (polarity).

8

ADA-401WP

ADA-401WP

VDD

GND

1-W

Rx+

Tx+/ A

Tx-/ B

GND

Rx-

Vss-

Vss+

V+

10–30VDC

3W

V-

1-WIRE (2W) Bus

1-WIRE

Connector

RS485/RS422

Connector

Power Supply

DS18B20 Sensor

DS18B20 Sensor

DS18B20 Sensor

Содержание ADA-401WP

Страница 1: ...User manual ADA 401WP 1 WIRE to MODBUS RTU Measuring Module 1 io_ada 401wp_v 1 24_en ADA 401WP Copyright 2001 2017 CEL MAR sp j...

Страница 2: ...1 SENSOR DISPLACEMENT 13 5 3 2 2 SENSORS EXCHANGE 13 5 3 2 3 CHANGING TEMPERATURE SENSORS ORDER BY THE USE OF AAS PROCEDURE 13 5 3 3 SENSORS REMOVING 14 5 3 4 MEASUREMENT CHANNEL PARAMETERS CONFIGURAT...

Страница 3: ...MEASURING CHANNEL 4X 3X REFERENCES 24 7 3 1 8 FUNCTION 0x03 0x04 READOUT OF CO2 CONCENTRATION MEASURING CHANNEL 4X 3X REFERENCES 24 7 3 1 9 FUNCTION 0x03 0x04 READOUT OF TEMPERATURE VALUE OF SENSOR PT...

Страница 4: ...ly of the device if it is enabled This may result to short circuit and damage the device The device can not be used for applications that determine human life and health eg Medical 1 3 CE LABEL The CE...

Страница 5: ...485 line is made on the basis of 600W protectors diodes and fuses To RS485 Bus can be connected 32 devices ADA 401WP Additional converter like ADA I1040 RS232 to RS485 or ADA I9140 USB to RS485 enabl...

Страница 6: ...erter from power circuit device that generates large impulse interference such as transmitters contactors 3 1 ASSEMBLING ADA 401WP enclosure is adapted to assembly on TS 35 DIN35 rail To install shoul...

Страница 7: ...Bd Should be used Line Termination resistor if the distance is over 1000m 9600Bd or 700m 19200Bd transmission Example connection of Rt connected to screw terminal block of RS485 422 interface are show...

Страница 8: ...500 However when building the network remember that each sensor is a shortening of 0 5 meters and 100 meters of cable causes additional capacity load data line 5nF increasing signal distortion The rea...

Страница 9: ...ecking RS485 interface Diagnosis 1 WIRE interface Diagnostic System Diagnostic Measurement channels Diagnostic 5 CONFIGURATION Configuration of ADA 401WP module should be made by the use of ADAUtil so...

Страница 10: ...disable disable manufacturer setting Errors that are signalled by short sound errors of sensors searching errors of reading temperature from sensors errors in RS485 communication errors of CRC sensor...

Страница 11: ...ingle reading sensors and Enable write TL and TH registers for DS18xxx are available from 2 005 firmware version and 1 7 1 0 version of ADAUtil 5 2 5 AUTOMATIC ASSIGN SENSORS TO MEASUREMENT CHANNELS A...

Страница 12: ...the table below Table indications of sensors Sensor Unit of measurement Sensor Unit of measurement Temperature C voltage converter 0 10V DC V U10 Relative humidity RH current converter 0 2mA DC mA A2...

Страница 13: ...iguration to module memory by pressing button Save Configuration to Module To the module memory will be saved only configuration of measuring channels which fields were marked in ping 5 3 2 3 CHANGING...

Страница 14: ...hPa to 12 70hPa for digital atmospheric pressure sensors DES 216 AP DES 300 AP etc Enable activation this field will cues actualisation of measurement and status for channel deactivation will cues blo...

Страница 15: ...in loaded file can be changed the module software Process of software update is visualized by ADAUtil in use of Progress Window and after proper update confirmed by correct message Fig 11 Choice of s...

Страница 16: ...mode value visualization of temperature measurement with the 0 5 C accuracy transmission errors on the 1 WIRE bus restore factory default and reset register Set the SW1 microswitch as in the table bel...

Страница 17: ...ter counter of Button the number of RST Reset button Register counter of Brown On specifies the number of the operating voltage drops below allowable voltage level After that can be set the switch sec...

Страница 18: ...ble below SW1 1 SW1 2 OFF OFF Yellow LED will be OFF 6 3 DIAGNOSTIC OF MODBUS PROTOCOL After finishing diagnostic of measurement channels of each ADA 401WP module in installation can be started diagno...

Страница 19: ...ters of channels 6 3 1 CONFIGURATION OF MODBUS RTU COMMUNICATION MODBUS Monitoring window has options for configuration of MODBUS RTU communication Module Address 1 247 enter the address of ADA 401WP...

Страница 20: ...sation of measurement and status for channel deactivation will cues block actualisation Assigned activation this field will cues adding a sensor to the Channel Deactivation will cues that in case of n...

Страница 21: ...condition R 16 bit register 30202 40202 1 201 Channel condition R 16 bit register 30203 40203 2 202 Channel condition R 16 bit register 30204 40204 3 203 Channel condition R 16 bit register 30204 4020...

Страница 22: ...re C 100 PT1000 sensor s temperature C PT1000 10 Relative humidity RH 10 0 10VDC transducer V U10 100 Lighting natural or unnatural Lux 10 0 20mADC transducer mA A20 100 Sunlight SLux 10 Circuit DS240...

Страница 23: ...during inquiry converting 03 CRC Lo 1 byte 04 CRC Hi 1 byte 7 3 1 2 FUNCTION 0x03 0x04 READOUT OF RELATIVE HUMIDITY FROM MEASURING CHANNEL 4X 3X REFERENCES Function 0x03 0x04 are used for readout of...

Страница 24: ...CTION 0x03 0x04 READOUT OF CO2 CONCENTRATION MEASURING CHANNEL 4X 3X REFERENCES Function 0x03 0x04 are used for readout of the value from measuring channel sensor The value from measuring channel sens...

Страница 25: ...erial number 40 0 402 Byte 4 of serial number 01 Bajt 5 of serial number 00 0 403 Byte 6 of serial number 00 Bajt 7 of serial number 23 Query of circuit serial number from channel nr 0 Byte no Designa...

Страница 26: ...status Byte Hi from ver 1 008 firmware 0 Sensor in processing 0 No 1 Yes 0 Short circuit on the 1 Wire bus 0 No 1 Yes 1 Sensor detected 0 No 1 Yes 1 DS18xx circuit present on 1 WIRE bus 0 0 No 1 Yes 2...

Страница 27: ...1 byte 83 84 02 Error code 1 byte 01 unknown function 02 unknown data address 03 unknown data value 04 unknown error while inquiry converting 03 CRC Lo 1 byte 04 CRC Hi 1 byte 8 SPECIFICATION TECHNICA...

Страница 28: ...ng Degree of casing protection IP40 Degree of terminal protection IP20 Weight 0 10 kg According to standard DIN EN50022 DIN EN43880 Location during work Free Mounting method On the rail compliant with...