1. GENERAL INFORMATION
Thank you for your purchase of
CEL-MAR Company
product. This product has been completely tested and is covered by a two year
warranty on parts and operation from date of sale.
If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48
41 362-12-46 or e-mail [email protected].
1.1. WARRANTED INFORMATION
ADA-401WP
module is covered by a two year warranty from date of sale. The warranty does not cover damage caused from improper
use, materials consumption or any unauthorized changes. If the product does not function (is damaged), or not operate in accordance
with the instructions will be repaired.
All warranty and no warranty repairs must be returned with paid transport and insuring to the
CEL-MAR Company.
CEL-MAR Company
under no circumstances won't be responsible for ensuing damage from improper using the product or as a result
of random causes: the lightning discharge, the flood, the fire and the like.
CEL-MAR Company
is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing
from using or the impossibility of using this product.
In specific cases
CEL-MAR Company
discontinue all warranties and in particular do not follow the user manual and do not accept
terms of warranty by the user.
1.2. GENERAL CONDITIONS FOR SAFE USE
The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged so
as not to be exposed to trampling, attaching, or pulling out of the circuit.
Do not put device on the wet surface.
Do not connect devices for nondescript powering sources,
Do not damage or crush powering wires.
Do not make connection with wet hands.
Do not adapt, open or make holes in casings of the device!
Do not immerse device in water or no other liquid.
Do not put the fire opened on device sources: candles, an oil lamps and the like.
Complete disable from the supply network is only after disconnecting the power supply circuit voltage.
Do not carry out the assembly or disassembly of the device if it is enabled. This may result to short circuit and damage the device.
The device can not be used for applications that determine human life and health (eg. Medical).
1.3. CE LABEL
The CE symbol on the device CEL-MAR means compatibility with electromagnetic compatibility Electromagnetic
Compatibility Directive
EMC 2014/30/WE.
Declaration of Conformity is available by contact with Technical Service
(email: [email protected]; phone: +48 41 362-12-46)..
1.4. ENVIRONMENTAL PRESERVATION
This sign on the device inform about putting expended device with other waste materials. Device should send to the
recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)
1.5. SERVICE AND MAINTENANCE
The
ADA-401WP module
does not require the servicing and maintenance.
Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail
.
1.6. PACK CONTENTS
Module is delivered with: User Manual, Line terminators 120W (2 pcs), CD-ROM with ADAUtil software.
2. PRODUCT INFORMATION
2.1. PROPERTIES
●
Possibility of creating networks on the basis of RS485 bus to which are being connected 1-wire sensors,
●
1-WIRE to MODBUS-RTU protocol conversion,
●
Supporting 1-WIRE interface circuits: DS1820, DS18S20, DS18B20, DS1822, DS2438Z, DS2401.
●
Temperature, humidity and atmospheric pressure measurement from the 64 digital sensors,
●
300m 1-WIRE bus distance - depend on sensor's number and connection method of them and cables,
●
Accuracy dependent on sensor's selection: for DS1820, DS18S20 – 0,50°C; for DS18B20, DS1822 – 0,0625°C,
●
RS-485 network baud rate up to 230,4 kbps,
●
1-WIRE network baud rate: Standard up to 16,3 kbps, Overdrive up to 142 kbps,
●
Stable power supply 10-30 VDC, power consumption up to 3W, depend on sensors number and type,
●
3kV= galvanic isolation between RS-485 interface and power supply,
●
~3kV= opto-isolation in signal channel between RS-485 and 1-WIRE interface,
●
Protection against power supply reverse connection,
●
Integrated short circuit protection and over-voltage protection on RS-485 and 1-WIRE networks,
●
Screw terminal block connectors for all connections,
●
DIN 43880 standard - mounting in typical electro-installation unit,
●
Rail mounting according to DIN35 / TS35 standard,
●
Dimensions (W x D x H) 53mm x 62mm x 90mm.
4