LOCATION
The heater can be positioned in the corner of a ceiling but for better heat distribution at least 600mm from
each wall is preferable.
The unit should not be positioned over desks, counters or high level display racking wherever a constant flow
of heated air may be uncomfortable or cause overheating of equipment.
If required the unit can be covered with non flammable insulating material to maintain the integrity of the
ceiling insulation.
The heater must be installed at a minimum of 2 m and a maximum of 3m from the floor.
CONTROL
Remote Switch
Thermostat
The Remote Switching Unit allows ON/OFF, Fan only with 2.25 or 4.5 kW.
A thermostat of 25A rating can be connected in the power supply to the Remote switch thus switching the
unit off totally when set temperature is reached. Alternatively a thermostat and contactor can be used.
CONTENTS
Remove from carton and check contents ;
- heater unit
- ODH-RSW three switch control unit
5mm fixing holes
Heater cover
Connection cover
SAFETY
The correct procedures for working at height must be adopted when installing this heater.
The heater must be installed by a suitably qualified person in accordance with current regulations.