CONTROLS

Control is by the 3 switches located next to the outlet grille.

Switch positions are:-

I/O:  

              

- Fan on.

Middle red:

      

- Fan and 1kW heat.

End red:

           - Fan and 2kW heat.

  

Both red:           

- Fan and 3kW heat

Note: the switches are electrically interlocked to ensure the heat cannot be on without the fan operating.

CLEANING

The heater should be cleaned occasionally to reduce the build up of dust which may cause the unit to 

overheat.  

OVER TEMPERATURE CUT OUT

To RESET -

Do not cover the unit

 

 

 

Should the heater exceed normal operating temperature the over temperature cut out on the heating 

element will operate.

 

   switch off power to the unit and allow to cool before switching on again. If the problem persists 

consult a suitably qualified person.  

Note:- 

 

 

 

 

 or allow  the inlet grille to be obstructed as this could cause over heating and 

possible damage.

The Manufacturers reserve the right to change the specification without prior notice   EO&E

Please keep these instructions for future reference

P01

Commercial Electric Heat Limited

           HAWICK TD9 8SL

No

Part No

Description

No

Date

Revision

Title

Rev

Drawing No.

Date

Drawn by

Scale

L011

2

1

L

L

2kW

1kW

N

N

ODH-W-001

2

nts

NEB

21.11.93

ODH-3000 

Over Door Heater

3

Connector 

Block

5

Rocker 

Switches

Heating element incorporates over temperature

cut out
To reset:-

Switch off and allow to cool( 5 minutes) then

restore supply
Heater does not function again until power has

been removed from cut out

1

Heating 

Element

4

6

Blower 

Unit

Over temp

cut out

2

Fan

Motor

Schematic diagrams

2kW

1kW

1
2
3
4

B081-01
D002-01
F003
C001

Heating element
Fan motor
Connector block
Blower unit

5

6

E015

SPST 16A switch

Over temp cut out

Fan

1kW

2kW

1

2

10/7/95

08/04

Replace 3way switch with 

3 single way switches 
add external cut out

WARRANTY 

This product is guaranteed, in accordance with our Conditions of Sale, for a period of 12 months from date of 

purchase. We will repair or replace, at our discretion, any part found to be defective. We cannot accept 

responsibility for any consequential liability. 

The warranty will be invalid if the heater has not been installed in accordance with these instructions.

This does not affect your statutory rights.

Commercial Electric Heat Limited

Burnfoot Industrial Estate 

HAWICK

Roxburghshire

TD9 8SL

Tel 01450 372103 Fax 01450 377800

Email [email protected] Web www.cehltd.co.uk

Отзывы: