5.05 Run an AC line cord into the weatherproof housing. Only a licensed electrician
should install the AC line, and this should be done in accordance with all
applicable codes and regulations. Locate the strobe light circuit board on the
telephone assembly, which is located underneath the main 660-000 printed
circuit board. The strobe light circuit board has a five position terminal strip on
it. Attach the AC line cord to the AC contacts, as labeled, on the terminal strip.
The strobe light wires will already be connected to the terminal strip. The
ground wire from the strobe light should be connected to any suitable earth
ground. Please refer to the wiring diagram on page 18 of this manual. Be
certain to seal any open gaps on housing, when wiring is completed, in order to
maintain the weatherproof integrity. Water can follow wires into openings if not
properly sealed. Simple silicone sealer is normally sufficient.
5.06 Plug the modular line cord from the faceplate assembly into the RJ11C terminal
block. Dress the line cord away from the security screws and seat the faceplate
into the weatherproof housing.
5.07 Carefully return the telephone assembly to the housing, securing it in place with
the four (4) security screws and security tool.
5.08 Telephone line wiring for modular jack: