Issue 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
7
PROGRAMMING CONTINUED…
3.08
Enter # 0 0 followed by a series of ten (10) digits selected from the options
below.
Some of the digits allow a choice and others simply provide an arbitrary
number. An entry MUST be made for each of the ten digits, in order for the
phone to be properly programmed.
Digit 1:
0
Always 0 for this model
.
Digit
2:
1
Always 1 for this model
.
Digit
3:
0 No Conversation Time-Out.
1-9 Minutes Conversation Time-Out. (the call will automatically be terminated after
the selected number of minutes).
Digit
4:
0
Always 0 for this model.
Digit
5:
0
Always 0 for this model
.
Digit
6:
0 Disable Second Number Dialing and ADA feature.
1-9 Activate Second Number Dialing (number of rings before retry) and ADA feature.
Digit
7:
0
Always 0 for this model
Digit 8: (PBX Access – see section 3.9)
0 Do not dial PBX access number stored in Location #l8.
1 Dial PBX access number stored in Location #18.
Digit
9:
0
Always 0 for this model.
Digit
10:
0 No Wink Detect.
1-9 Wink Detect (l = 50ms incremental to 450ms,
5 = 250ms
recommended
).