ISSUE 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
6
4.0
OPERATION
Lift the handset.
A normal phone conversation may take place as determined by the
set up/application.
5.0
INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS
5.1
Using a 301-037 security tool (sold separately), loosen and remove the
security screw.
5.2
The security tool is for a standard 5/32" button head screw generally used
on the framework of the phone booths.
5.3
Separate the cover assembly from the backplate assembly.
5.4
The backplate assembly may be installed on any standard backboard.
5.5
Run the inside station wire through the backplate assembly and terminate
on to the RJ11C terminal block on the backplate.
5.6
The use of a gas tube station protector is recommended. The station
ground should not exceed 50 ohms.
5.7
Plug the modular line cord from the cover assembly into the RJ11C
terminal block.
5.8
Dress the line cable away from the security screw and install the cover
assembly by inserting the tabs into the slots on top of the backplate.
5.9
Secure the cover assembly by tightening the security screw.
6.0
TESTING
6.1
Program the phone according to section 3.0.
6.2
Lift the handset.
6.5
A normal phone conversation takes place.
6.6
When the call is ended, hang up.