LOCATION #00:
(
OPTION TABLE
)
#00 __ __ __ __ 0_ 0_ 1_ __ __ 5_
Digit: 1 2 3 4 5 6 7 8 9 10
Digit 1:
0 Call restrictions are in effect. (Default)
1 No call restrictions.
Digit
2:
0 No incoming calls allowed. (Default)
1 Incoming calls allowed.
Digit
3:
0 No Conversation Time-Out. (Default) For
Emergency
Button
1-9 Minutes Conversation Time-Out
Digit
4:
0 No Conversation Time-Out. (Default) For
Call
Button
1-9 Minutes Conversation Time-Out
Digit
5:
0
Always 0 for this model
. (Default)
Digit
6:
0
Deactivate ADA feature (changing LED).
9 Activate ADA feature (changing LED).
Digit
7:
1
Always 1 for this model
Digit
8:
0 Do not dial PBX access number #l8 (Default)
1 Dial PBX access number stored in Location #18 For
Call
Button
Digit
9:
0 Do not dial PBX access number #02. (Default)
1 Dial PBX number stored in location #02. For
Emergency
Button
Digit
10:
0 No Wink Detect
l-9 Length of the Wink (l = 50ms incremental to 450ms – entering a 5 is
recommended)