7.0 SPECIFICATIONS 
 

 
 

INPUT POWER: 

 

 

C.O. Line powered 

 
 LOOP 

CURRENT: 

  25ma 

minimum 

 
 IMPEDANCE:   600 

ohms 

 
 SIGNALING: 

   DTMF, 

70ms 

tone, 

50ms 

spacing 

 
 OUTPUT: 

   -10.0 

to 

-12.0dbm 

 
 HEARING 

AID 

 

 COMPATIBLE: 

  Meets 

EIA 

standards 

 
 ENVIRONMENTAL: 

  Temperature 

 

0oC 

to 

50oC 

      Humidity 

 

20%-90% 

non 

condensating. 

 
 PROGRAMMING: 

  Via 

DTMF 

keypad. 

 
 

TELEPHONE PANEL: 

 

Brushed 16 ga. Stainless Steel  

                     

DIMENSIONS: 

 

 

10.12" Wide x 13.12" High x 2.75" Deep 

                       

 

 

 

 

 MOUNTING: 

   Vertical 

surface 

mount 

 
 

MEMORY RETENTION: 

 

Lithium Battery – Long Life 

 
 FCC 

REGISTRATION: 

 BW88T7-13823-TE-T 

 
 

UL LISTED NO.:       

 

6OF5 

 
 RINGER 

EQUIVALENCE: 

 0.8A 

 

TYPE 

JACK: 

   RJ11C 

 
 
 
 
 
 
 
 

Содержание SSP-369-FE

Страница 1: ...MODEL SSP 369 FE STAINLESS STEEL PANEL TELEPHONE EQUIPPED WITH CAC6 00 FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street Engineering Company Okeechobe...

Страница 2: ...CO for assistance MODEL NUMBER MODEL SSP 369 FE EQUIPPED WITH CAC6 00 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when...

Страница 3: ...GRAMMING CONTINUED 8 PROGRAMMING CONTINUED 10 PROGRAMMING CONTINUED 12 PROGRAMMING CONTINUED 13 4 0 TESTING OPERATION 14 TESTING OPERATION CONTINUED 15 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 15 6 0...

Страница 4: ...esigned to withstand abuse and fraudulent call attempts The phone may be programmed to implement call restrictions allow incoming calls select the width of the dial tone detection window mute the micr...

Страница 5: ...wait for dial tone before beginning programming 3 4 The normally configured keypad is utilized to perform all of the programming of the telephone Please refer to the diagram on the page 7 Utilizing th...

Страница 6: ...0 Mute the microphone until the user dials a digit 1 Unmute the microphone after the access number is dialed Digit 5 0 DTMF dialing 1 10 PPS pulse dialing 2 20 PPS pulse dialing Digit 6 0 no call time...

Страница 7: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 7 DIAGRAM PROGRAMMING KEYPAD LOCATION...

Страница 8: ...ill program the phone to dial 555 1212 when the 1 button key is pressed You must enter the key the 0 key and the 1 key to program the 01 location The same is true for all twelve locations The keypad l...

Страница 9: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 9 SBA KEYPAD CONFIGURATION 1 01 7 07 2 02 8 08 3 03 9 09 4 04 10 5 05 0 11 6 06 12...

Страница 10: ...ocation For example Entering 1818005551212 will program the phone to dial 1 800 555 1212 approximately one second after it dials the number stored in location 19 Combining the examples from this secti...

Страница 11: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 11 NORMALLY CONFIGURED KEYPAD 1 2 3 4 5 6 7 8 9 0...

Страница 12: ...__ __ __ __ 54 __ __ __ __ __ __ __ __ __ __ __ 35 __ __ __ __ __ __ __ __ __ __ __ 55 __ __ __ __ __ __ __ __ __ __ __ 36 __ __ __ __ __ __ __ __ __ __ __ 56 __ __ __ __ __ __ __ __ __ __ __ 37 __ _...

Страница 13: ...alling patterns you program the phone to tell it which patterns to allow In turn it will block all others Take a moment to look over the examples below When you are finished enter the key followed by...

Страница 14: ...eypad Each button key that you press should release the number that was programmed into it If not hang up the phone and repeat sections 3 2 3 3 3 6 and 3 11 only If this does not solve the problem ple...

Страница 15: ...is fails hang up and repeat sections 3 2 3 3 3 5 and 3 11 only If this does not solve the problem please refer to section 10 2 4 9 Also be sure to determine that the microphone is muting as it was pro...

Страница 16: ...terminate the Tip and Ring wires to the green and red wires of the RJ11C terminal block located inside the box 6 6 The use of a gas tube station protector is recommended The station ground should not...

Страница 17: ...0 to 12 0dbm HEARING AID COMPATIBLE Meets EIA standards ENVIRONMENTAL Temperature 0oC to 50oC Humidity 20 90 non condensating PROGRAMMING Via DTMF keypad TELEPHONE PANEL Brushed 16 ga Stainless Steel...

Страница 18: ...kswitch cradle 301 581 Tongue and bracket assembly 301 018 30 Modular cord 301 051 Modular jack 301 052 Grommet 11020 Stainless steel panel 11025 Apparatus box 9026 10 32 x 1 2 security screw 650 521...

Страница 19: ...work through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE TELEPHONE COMP...

Страница 20: ...attached to the defective unit This information must be inside the shipping container 10 2 DIRECT ALL INQUIRES TO CEECO Repair Department 863 357 0798 telephone 863 357 0006 facsimile info ceeco net...

Страница 21: ...any kind which have been caused by neglect abuse or improper operation of equipment CEECO will repair or replace any unit during this period if found to be defective for reasons other than abuse and...

Страница 22: ...hen programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life MOVE THE MINI JUMPERS TO THE ON POSITION BE...

Отзывы: