background image

MHW-341-D-ATD-11-ISSUE4.0 

 
 
 
 
 
 

SERVICE MANUAL 

 

FOR 

 

MODEL MHW-341-D 

 

MAGNETIC HOOKSWITCH WALL 

 TELEPHONE  

 
 
 

EQUIPPED WITH ATD-11 AUTOMATIC DIALER  

 

 
 
 

 

 

 
 
 
 
 
 
 

 

 

 

        

Serving the Telephone Industry Since 1930 

Communication 

Equipment 

      

  

 

 

 

 

519 W South Park Street

 

& Engineering Company

 

       

 

 

 

 

Okeechobee, 

FL 

 

34972

 

 

 

 

 

 

 

 

 

 

 

     

Voice:  863-357-0798 

 

 

 

 

 

 

 

 

 

     

Fax:    863-357-0006 

Содержание MHW-341-D

Страница 1: ...MHW 341 D MAGNETIC HOOKSWITCH WALL TELEPHONE EQUIPPED WITH ATD 11 AUTOMATIC DIALER Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street Engineering Company Okeech...

Страница 2: ...when calling CEECO for assistance MODEL NUMBER MODEL MHW 341 D SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when calling for tec...

Страница 3: ...0 GENERAL 4 3 0 PROGRAMMING 5 PROGRAMMING DIAGRAM PROGRAMMING CONTINUED 6 PROGRAMMING CONTINUED 7 4 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 7 5 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 8 6 0 TEST...

Страница 4: ...tch Wall Telephone is equipped with a magnetically operated hookswitch The MHW 341 D is designed for special applications where a telephone must be sturdy and attractive and automatically dial a singl...

Страница 5: ...igits If the number to be programmed is a local call position the J1 mini jumper on the B position bridging the center and right copper pins 3 4 If a 3 digit area code is to be dialed the J3 mini jump...

Страница 6: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 6 PROGRAMMING DIAGRAM...

Страница 7: ...ately as possible measure the time delay between the moment the handset is lifted and the moment the phone receives dial tone Try it several times If this time is consistently 1 second or less positio...

Страница 8: ...it contains required over voltage protection circuitry 5 4 The use of a gas tube station protector is recommended The station ground should not exceed 50 ohms 5 5 Plug the modular line cord from the c...

Страница 9: ...muted while the phone is dialing Normal phone operation should follow when the call is answered 6 3 When the call is complete hang up the phone 6 4 Place a call to the phone 6 5 The phone should ring...

Страница 10: ...NALING DTMF 70ms tone 50ms spacing HEARING AID COMPATIBLE Meets EIA standards ENVIRONMENTAL Temperature 0 C to 50 C Humidity 20 90 non condensating PROGRAMMING Via Hardware Matrix Switch TELEPHONE COV...

Страница 11: ...CRIPTION 11013 Stainless Steel Housing with backplate 350 169 ATD 11 Automatic Tone Dial 12027 Network 6017 Reed Switch 14010 Modular Cord 9023 1 4 20 3 4 Security Screw 9005 Grommet 14014 Modular Jac...

Страница 12: ...Telephone Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE T...

Страница 13: ...ctive unit This information must be inside the shipping container 10 2 DIRECT ALL INQUIRES TO CEECO Repair Department 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 10 3 NO...

Страница 14: ...or replacement of any part found to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neg...

Отзывы: