Important:

 

The scale is not printed on the sensor. The 
potentiometer can be adjusted linearly from 0.4 m to 
2.0 m; see Figure 3 below. 

 

Take a small screw driver and turn the potentiometer 
to the required position.

(all dimensions in mm)

Figure 3: 

Detection field using potentiometer

Table 1: 

 Parameter - detection field

6.  Installation

Important:

The TOF/Start-EA must be mounted at a 

minimum 10° 

mounting angle

 to the ground.

Figure 4: 

Mounting angle of TOF/Start-EA

7.  Input / Output description and 
 

electrical connection

Generally the TOF/Start-EA has one output that is triggered 
if the detection field is interrupted. For this purpose, a 
push-pull output is used. With the logic selector (gray wire, 
Figure 6), the logic of the output signal can be configured  
for “HIGH“ on object or “LOW“ on object operation 
(Figure 5), according to the controller requirements.

The logic selection is performed during start-up.

Figure 5: 

Output (PNP/NPN) logic

Figure 6: 

Connection diagram

8.  Start-up

1.  Switch on mains and power up.
2.  Check if LED lights up.
3.  Check the distance setting and the reaction of the 

sensor, including the status LED, by placing an object 
into the detection area at different heights and widths.

      

0 ... 1000

Area without cross-traffic

x-axis

y-axis

70°

20°

x = min. 400 ... max. 2000

y = min. 400 ... max. 2000

2 m

1.2 m

0.4 m

0.8 m

1.6 m

2 m

1.2 m

0.4 m

0.8 m

1.6 m

Parameter

Value

Operating range
x-axis

Min.: 0 ... 400 mm
Max.: 0 ... 2,000 mm 

Operating range
y-axis

Min.: 0 ... 400 mm
Max.: 0 ... 2,000 mm

Aperture angle

70°

U

SP

0 V

Output

Logic selector connected to GND (0 V)

U

SP

0 V

Output

Logic selector connected to U

SP

Con

tr

oller

U

SP

 

GND (0 V)

n.c.

Selectable output logic

Output

n.c.  =  not connected and isolated

n.c.

black

brown

green

blue

white

gray

TOF/Start-EA

10°

Содержание TOF/Start-EA

Страница 1: ...TOF Start EA Installation and Operation Manual 115 077 180226 V 1 0 English Pages 2 10 CEDES AG is certified according to ISO 9001 2015 RoHS ...

Страница 2: ...cience Park CH 7302 Landquart Switzerland CEDES AG reserves the right to modify or change technical data without prior notice Contents 1 About this manual 2 1 1 Measurements 2 1 2 Related documents 2 1 3 CEDES headquarters 2 2 Safety information 3 2 1 Non intended use 3 3 Symbols safety messages 3 3 1 Safety messages categories 3 4 Introduction 4 4 1 Application 4 4 2 Features of the TOF Start EA ...

Страница 3: ...or death 2 1 Non intended use The TOF Start EA must not be used for Protection of dangerous machines Equipment in explosive atmospheres Equipment in radioactive environments Use only specific and approved safety devices for such applications otherwise serious injury or death or damage to property may occur 3 Symbols safety messages 3 1 Safety messages categories Warning of serious health risks Cau...

Страница 4: ...iguration 5 1 Type of threshold setting The distance at which the sensor triggers an output is the threshold The TOF Start EA requires a threshold setting for the x axis as well as the y axis using potentiometers A factory setting as well as a mixture of potentiometer and preset are also possible on request Note The sensor uses a 120 mm 4 72 in hysteresis The hysteresis is the difference between t...

Страница 5: ...nfigured for HIGH on object or LOW on object operation Figure 5 according to the controller requirements The logic selection is performed during start up Figure 5 Output PNP NPN logic Figure 6 Connection diagram 8 Start up 1 Switch on mains and power up 2 Check if LED lights up 3 Check the distance setting and the reaction of the sensor including the status LED by placing an object into the detect...

Страница 6: ... No object HIGH LOW HIGH LOW t2 t3 t1 t4 Off Dimmed Dimmed Bright X X X X HIGH on object Output Power supply LED status LOW on object Output Object detection Time Value ms Power on time t1 1 000 Max response time Area without cross traffic 1 m Area with cross traffic 1 m t2 200 400 Release time t3 200 Min switching time t4 200 ...

Страница 7: ...ins at a 1 meter distance from the sensor Figure 10 Detection field free person moves towards the door entrance area LED status is dimmed Figure 11 Person is detected entering detection area moving towards the door entrance area LED status is bright Figure 12 Detection field free Person moves to cross the door entrance area LED status is dimmed Figure 13 Sensor recognizes the person is moving cros...

Страница 8: ...detection field is free Figure 17 A static object is placed in the detection field i e a trash bag The object will be detected Figure 18 After 30 s the static object will be blanked out and the TOF Start EA continues its operation with the new geometry of the detection field 13 Trouble shooting If the problem persists please contact your local CEDES representative www cedes com LED dimmed LED dimm...

Страница 9: ...aterial Polycarbonate Housing color Black Enclosure rating IP65 Temperature range 20 C 65 C Electrical Supply voltage USP 24 VDC 20 Current consumption 50 mA at 24 VDC peak max 0 5 A Output PNP NPN push pull Max response time Area without cross traffic 1 m 200 ms Area with cross traffic 1 m 400 ms Min switching time 200 ms Power on time 1 s Connection cable and electrical connection Sensor Length ...

Страница 10: ... Dimensions 17 1 Sensor Measurements all dimensions in mm and inches 17 2 Mounting bracket Measurements all dimensions in mm and inches 57 2 24 34 1 34 52 2 05 44 5 1 75 41 5 1 63 29 1 14 68 35 2 69 31 7 1 25 25 33 35 1 31 40 1 57 51 4 2 02 ...

Страница 11: ...TOF Start EA English CEDES V 1 0 11 ...

Страница 12: ...CEDES AG Science Park CH 7302 Landquart Phone 41 81 307 2323 Fax 41 81 307 2325 info eu cedes com www cedes com TOF Start EA ...

Отзывы: