4.  Introduction

The TOF/Start-EA (Entrance Automation) is a compact yet 
powerful sensor which detects people and objects and 
reliably triggers an opening signal. The sensor has been 
specially developed as a door opener for both pedestrian 
doors and industrial doors. Its TOF technology enables 
the TOF/Start-EA to operate with all types of backgrounds 
without any need to recalibrate. Its key advantage is its 
ability to reliably distinguish between traffic passing by 
(cross-traffic) and traffic that intends to go through the 
door. This ability to automatically ignore cross-traffic 
greatly boosts energy-saving and reduces mechanical 
stress on the doors caused by unnecessary openings.

4.1  Application

Figure 1: 

TOF/Start-EA ignores cross-traffic via intelligent  

 

door opening

4.2  Features of the TOF/Start-EA

•  Excellent detection capability, independent of 

reflectance

•  Ignores cross-traffic via intelligent direction 

recognition 

•  Individual setting of the detection area
•  Detection area operates with all types of background
•  Insensitive to ambient light

4.3  Type description

Figure 2: 

Type description

5.  Configuration

5.1  Type of threshold setting

The distance at which the sensor triggers an output is the 
threshold. The TOF/Start-EA requires a threshold setting 
for the x-axis as well as the y-axis using potentiometers. A 
factory setting, as well as a mixture of potentiometer and 
preset, are also possible on request.

Note:

 The sensor uses a ±120 mm (±4.72 in) hysteresis. 

The hysteresis is the difference between the switching 
points changing the status from 'free field' to 'object 
detected' and back from 'object detected' to 'free field', 
compared to the nominal limit. 

5.1.1 Threshold setting via potentiometer

The threshold distance at which the sensor triggers 
an output is set with a potentiometer for the x-axis and 
y-axis. This is done using the potentiometer at the back 
of the sensor. If the sensor points to a background, the 
distance of the switching threshold to the background is 
recommended to be set at 150 mm.

TOF/Start -EA – aa – b – c – d – eee – f; g,g*h,h

aa

 

:  Aperture angle in °

Threshold

settings

Only if Preset 

type

b

 

:  x-axis

 

  N 

Potentiometer

 

  T 

Teach-in

 

  P 

Preset

c

 

:  y-axis

 

  N 

Potentiometer

 

  T 

Teach-in

 

  P 

Preset

f

 

:  - 

Non-blanking

 

  B 

Blanking

g,g

 

:  x-axis

 

  Protection field in m

h,h

 

:  y-axis

 

  Protection field in m

d

 

:  C 

Automatic calibration

eee

 

:  1PP  Output - PNP/NPN (push-pull)

 

  2PP  2*Output - PNP/NPN (push-pull)

 

  1NP  Output - NPN

 

  1PN  Output - PNP

 

  2NP  2*Output - NPN

 

  2PN  2*Output - PNP

Содержание TOF/Start-EA

Страница 1: ...TOF Start EA Installation and Operation Manual 115 077 180226 V 1 0 English Pages 2 10 CEDES AG is certified according to ISO 9001 2015 RoHS ...

Страница 2: ...cience Park CH 7302 Landquart Switzerland CEDES AG reserves the right to modify or change technical data without prior notice Contents 1 About this manual 2 1 1 Measurements 2 1 2 Related documents 2 1 3 CEDES headquarters 2 2 Safety information 3 2 1 Non intended use 3 3 Symbols safety messages 3 3 1 Safety messages categories 3 4 Introduction 4 4 1 Application 4 4 2 Features of the TOF Start EA ...

Страница 3: ...or death 2 1 Non intended use The TOF Start EA must not be used for Protection of dangerous machines Equipment in explosive atmospheres Equipment in radioactive environments Use only specific and approved safety devices for such applications otherwise serious injury or death or damage to property may occur 3 Symbols safety messages 3 1 Safety messages categories Warning of serious health risks Cau...

Страница 4: ...iguration 5 1 Type of threshold setting The distance at which the sensor triggers an output is the threshold The TOF Start EA requires a threshold setting for the x axis as well as the y axis using potentiometers A factory setting as well as a mixture of potentiometer and preset are also possible on request Note The sensor uses a 120 mm 4 72 in hysteresis The hysteresis is the difference between t...

Страница 5: ...nfigured for HIGH on object or LOW on object operation Figure 5 according to the controller requirements The logic selection is performed during start up Figure 5 Output PNP NPN logic Figure 6 Connection diagram 8 Start up 1 Switch on mains and power up 2 Check if LED lights up 3 Check the distance setting and the reaction of the sensor including the status LED by placing an object into the detect...

Страница 6: ... No object HIGH LOW HIGH LOW t2 t3 t1 t4 Off Dimmed Dimmed Bright X X X X HIGH on object Output Power supply LED status LOW on object Output Object detection Time Value ms Power on time t1 1 000 Max response time Area without cross traffic 1 m Area with cross traffic 1 m t2 200 400 Release time t3 200 Min switching time t4 200 ...

Страница 7: ...ins at a 1 meter distance from the sensor Figure 10 Detection field free person moves towards the door entrance area LED status is dimmed Figure 11 Person is detected entering detection area moving towards the door entrance area LED status is bright Figure 12 Detection field free Person moves to cross the door entrance area LED status is dimmed Figure 13 Sensor recognizes the person is moving cros...

Страница 8: ...detection field is free Figure 17 A static object is placed in the detection field i e a trash bag The object will be detected Figure 18 After 30 s the static object will be blanked out and the TOF Start EA continues its operation with the new geometry of the detection field 13 Trouble shooting If the problem persists please contact your local CEDES representative www cedes com LED dimmed LED dimm...

Страница 9: ...aterial Polycarbonate Housing color Black Enclosure rating IP65 Temperature range 20 C 65 C Electrical Supply voltage USP 24 VDC 20 Current consumption 50 mA at 24 VDC peak max 0 5 A Output PNP NPN push pull Max response time Area without cross traffic 1 m 200 ms Area with cross traffic 1 m 400 ms Min switching time 200 ms Power on time 1 s Connection cable and electrical connection Sensor Length ...

Страница 10: ... Dimensions 17 1 Sensor Measurements all dimensions in mm and inches 17 2 Mounting bracket Measurements all dimensions in mm and inches 57 2 24 34 1 34 52 2 05 44 5 1 75 41 5 1 63 29 1 14 68 35 2 69 31 7 1 25 25 33 35 1 31 40 1 57 51 4 2 02 ...

Страница 11: ...TOF Start EA English CEDES V 1 0 11 ...

Страница 12: ...CEDES AG Science Park CH 7302 Landquart Phone 41 81 307 2323 Fax 41 81 307 2325 info eu cedes com www cedes com TOF Start EA ...

Отзывы: