2.  Safety information

IMPORTANT!

READ BEFORE INSTALLATION!

The TOF/Spot was developed and manufactured using 

state-of-the-art systems and technologies. However, injury 

and damage to the sensor can still occur.

To ensure safe conditions:

 

Read all enclosed instructions and information.

 

Follow the instructions given in this manual carefully. 

 

Observe all warnings included in the documentation 

and attached to the sensor.

 

Do not use the sensor if it is damaged in any way.

 

Keep the instruction manual on site.

The TOF/Spot should only be installed by authorized and 

fully trained personnel! The installer or system integrator is 

fully responsible for the safe integration of the sensor. It is 

the sole responsibility of the planner and/or installer and/

or buyer to ensure that this product is used according to 

all applicable standards, laws and regulations in order to 

ensure safe operation of the whole application.

Any alterations to the device by the buyer, installer or user 

may result in unsafe operating conditions. CEDES is not 

responsible for any liability or warranty claim that results 

from such manipulation.

Failure to follow instructions given in this manual and/

or other documents related to the TOF/Spot may cause 

customer complaints, serious call backs, damage, injury or 

death.

2.1  Non-intended use

The TOF/Spot 

must not be

 used for:

•  Protection of dangerous machine
•  Equipment in explosive atmospheres
•  Equipment in radioactive environments

Use only specific and approved safety devices for such 

applications, otherwise serious injury or death or damage 

to property may occur!

3.  Symbols, safety messages

3.1  Safety messages categories

Warning of serious health risks

WARNING

Serious health risks

Highlights critical information for the safe use 

of the sensor. Disregarding these warnings 

can result in serious injury or death.

 

Follow the measures highlighted by the 

triangle-shaped arrows

 

Consult the safety information in Chapter 

2 of this manual

Caution of possible health risk

CAUTION

Possible health risks

Highlights critical information for the safe use 

of the sensor. Disregarding these warnings 

can result in injury.

 

Follow the measures highlighted by the 

triangle-shaped arrows

 

Consult the safety information in Chapter 

2 of this manual

Notice of damage risk

NOTICE

Risk of damage

Disregarding these notices can lead to 

damage to the sensor, the door controller  

and/or other devices.

 

Follow the measures highlighted by the 

triangle-shaped arrows

Symbol

Meaning

 

 

Single instruction or measures in no 

particular order

1. 

 

2. 

 

3. 

 

Sequenced instructions

•   

List, in no order of importance

à

Reference to a chapter, illustration or 

table within this document

Important

Important information for the correct 

use of the sensor

Содержание TOF/Spot

Страница 1: ...English Pages 2 12 Original version 113 009 200512 V 4 0 Installation and Operation Manual TOF Spot CEDES AG is certified according to ISO 9001 2015 RoHS...

Страница 2: ...odify or change technical data without prior notice Contents 1 About this manual 2 1 1 Measurements 2 1 2 Related documents 2 1 3 CEDES headquarters 2 2 Safety information 3 2 1 Non intended use 3 3 S...

Страница 3: ...ious call backs damage injury or death 2 1 Non intended use The TOF Spot must not be used for Protection of dangerous machine Equipment in explosive atmospheres Equipment in radioactive environments U...

Страница 4: ...l string replacement Loading dock stations Car barrier detection Figure 1 Car barrier detection 4 2 Features of the TOF Spot Exact distance setting independent of background Excellent detection capabi...

Страница 5: ...eguarded area One output signals the detection of an object within the detection area Figure 5 Replaces pull string door opening Figure 6 Warehouse doors Figure 7 Car park barriers Figure 8 Bed detect...

Страница 6: ...flat borders and where the edges are Important For proper functionality the remission range of the background or the object has to be between 2 90 Do not use high reflective retro reflective or mirror...

Страница 7: ...t using the potentiometer located at the rear of the sensor Important When setting with the potentiometer use Figure 12 as the settings are not printed on the sensor Take a small screw driver and turn...

Страница 8: ...stance This distance can only be changed by doing the setting process again 6 5 I type Initialized The I type has a specific detection range setting by factory according customer request Due to the po...

Страница 9: ...with the controller 8 1 Mounting of snap in housing The mounting hole recommended for flush mounting is 30 to 31 mm The sheet thickness cannot be greater 3 mm 30 mm 0 5 1 18 in 0 019 0 3 3 mm 0 011 0...

Страница 10: ...Open Figure 24 Timing diagram for relay output Time Value Power on time t1 1 000 ms Response time t2 60 ms Release time t3 60 ms Table 1 General timing table 12 LED signal LED status Description LED o...

Страница 11: ...and a little soapy water NOTICE Damage to the optical window Never use any solvents cleaners or mechanically abrasive towels or highpressure water to clean the sensors 15 Disposal The TOF Spot should...

Страница 12: ...DC Current consumption at 24 VDC 50 mA Peak current consumption 500 mA during power up at 24 VDC Output Solid state relay Max switching voltage 60 V Max switching current 150 mA Max power up time 1 s...