cegard/Mini-CC
English
4
© CEDES | V 1.0
Electrical connections are compatible with the CEDES MiniMax series.
GND (0 V)
Output
Selectable output logic
cegard/Mini-CC
M8, 4-pin
blue
black
brown
white
NPN
PNP
µC
Load
U
SP
i
Load
PNP
i
NPN
Troubleshooting
Sensor status
Action
General / unknown problem
`
Power off both cegard/Mini-CC edges and restart.
`
Check if the supply voltage on both edges is between
10 VDC and 30 VDC.
`
Check LED function (see "Mounting instructions").
Receiver edge output (black wire) is HIGH when the
detection area is free.
`
Connect output selector (white wire) on the receiver with
GND (blue wire), see "Selectable output logic".
Receiver edge output (black wire) is LOW when the
detection area is free.
`
Connect output selector (white wire) on the receiver with
U
SP
(brown wire), see "Selectable output logic".
Output signal is unstable when the elevator door closes.
`
Make sure no objects such as the door interlock assembly
enter the detection area during closure.
`
Make sure the edges do not swing or vibrate during
closure.
`
Make sure the edges are not covered by dust or dirt.
`
Make sure the receiver edge is not directly exposed to
strong infrared light sources such as sunlight.
Elevator doors are closing even when objects enter the
detection area.
`
Make sure the NO/NC selector is set correctly.
PNP/NPN output
4. Switch on the cegard/Mini-CC and test for correct function using the status LEDs on both edges.
Edge
LED Color
LED ON
LED OFF
Receiver (Rx)
Orange
Power OK
object detected
No power or
no object detected
Emitter (Tx)
Green
Power OK
No power
U
SP
0 V
Output
NO/NC selector connected to GND (0 V)
U
SP
0 V
Output
NO/NC selector connected to U
SP
or not connected
Selectable output logic