![Cedes cegard/Mini-CC Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/cedes/cegard-mini-cc/cegard-mini-cc_manual_2578766003.webp)
cegard/Mini-CC
English
© CEDES | V 1.0
3
`
Make sure both connectors are on top.
`
Make sure the detection area between the edges is not
interrupted by door wings, cables, etc.
`
Make sure the optical elements (black circles) on each
sensor edge are facing each other.
`
Make sure that the blue plug is plugged into the blue
connector and the white plug is plugged into the white
connector.
`
Improperly fixed and guided cables can reduce cable
lifetime drastically. Cable swinging and snagging in the
hoistway can lead to cable damage.
`
To avoid EMI problems, rout cegard/Mini-CC cables
as far away as possible from the door drive motor or
motor inverter (VVVF-drives).
Mounting restrictions for EN81-20 compatible models
Mounting instructions
brown
blue
black
white
U
SP
GND (0 V)
Output (push-pull)
Selectable output logic
Rx cable connection
brown
blue
black
white
U
SP
GND (0 V)
Not used
Not used
Tx cable connection
min. x
min. x
1
0
100
200
300
400
500
600
700
800
900
0
20
40
60
80
100
120
140
160
180
1.5
2
2.5
3
3.5
4
1
1.5
2
2.5
3
3.5
4
Max. distance between Rx and Tx (m)
Max. distance between Rx and Tx (m)
20 element system
33 element system
36 element system
No restrictions regarding the mounting
positions of the light curtain are in place.
x
(mm
)
x
(mm
)
min. x
min. x
min. x
min. x
min. x
Rx and Tx
Cabin walls
Cabin door
Area with a resolution
> 50 mm
x
Mounting position
Mounting position
Mounting position
1. Mount the cegard/Mini-CC edges onto the elevator.
2. Guide the cables to the elevator controller using
appropriate mounting material, e.g. cable protection
tubes, neoprene cable ties or cable guide wires
depending on the type of mounting kit used.
3. Connect the cegard/Mini-CC to the door controller.