Page 7
AES/EBU pin-out for the
DB25 connector
View from rear of unit
Channels
Pin
Hot
Cold
Grd
In
1 & 2
24
12
25
3 & 4
10
23
11
5 & 6
21
9
22
7 & 8
7
20
8
Out
1 & 2
18
6
19
3 & 4
4
17
5
5 & 6
15
3
16
7 & 8
1
14
2
unused:13
Fail-safe bypass
DnS 8 live units from serial number DnS-8-00992 onward have a fail-safe bypass
fitted as standard. Firmware v1.1.3 or later is required for this to operate correctly.
In the event of a power failure (or certain other major malfunctions) the Xlr inputs
become connected directly to the Xlr outputs by relays, bypassing the active
electronics of the unit. Once triggered, the fail-safe bypass can be cleared by
power-cycling the unit. note that the fail-safe bypass does not apply to signals
presented to the DB25 connector.
Audio output synchronisation
a BnC connector is provided. This will accept a DarS synchronisation signal
conforming to aeS11 or squarewave wordclock at the nominal sample rate.
The BnC sync input can be terminated (75Ohms) using the recessed rear panel
switch.
IMPORTANT NOTE:
The digital audio signals feeding the DnS 8 live must be at the same sample rate
and synchronous or clicks, ticks, or even loud broadband noise may result from the
consequent data errors.
Ethernet
The Ethernet connection allows you to upgrade the firmware (if required) and to
control the DnS 8 live using a standard web browser.
The MaC address is stated on the label on the rear panel of the unit and within the
status page.
Содержание dns 8 live
Страница 2: ...Page 2 Intentionally left blank ...