INSTALLATION
Figure 16 - Equipment Shutoff Valve
CHECKING GAS CONNECTIONS
Open
Closed
Equipment
Shutoff Valve
WARNING: Test all gas piping
and connections for leaks after
installing or servicing. Correct
all leaks at once.
WARNING: Never use an open
flame to check for a leak. Apply
a noncorrosive leak detection
fluid to all joints. If bubbles form,
there is a leak. Correct all leaks
at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect heater with its appliance main
gas valve (control valve) and equipment
shutoff valve from gas supply piping sys-
tem. Pressures in excess of 1/2 PSIG will
damage heater regulator.
2. Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas or using compressed air.
4. Check all joints of gas supply piping sys-
tem. Apply a noncorrosive leak detection
fluid to all joints. If bubbles form, there may
be a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff
valve to gas supply. Check reconnected
fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1.
Close equipment shutoff valve (see Fig-
ure 16).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas or using compressed air.
3. Check all joints from gas meter (natural
gas installations, see Figure 17) or from
propane/LP tank (propane/LP gas installa-
tions, see Figure 18) to equipment shutoff
valve. Apply a noncorrosive leak detection
fluid to all joints. If bubbles form, there is
a leak.
4. Correct all leaks at once.
LP REGULATOR INSTALL 2
Figure 18 - Propane/LP Fuel Supply
Propane/LP
Supply Tank
Gas Valve
Equipment
Shutoff Valve
Figure 17 - Natural Gas Supply
Gas Meter
Gas Valve
Equipment
Shutoff Valve
Содержание MD100TBF
Страница 26: ...www usaprocom com 200031 01B 26 PARTS MODEL MD100TBF 8 7 12 10 6 5 4 3 2 2 1 2 2 13 1 9 11 ...
Страница 28: ...www usaprocom com 200031 01B 28 PARTS MODEL MD200TBF 8 15 7 12 14 10 6 5 4 3 2 2 1 2 2 13 1 9 11 ...
Страница 62: ...www usaprocom com 200031 01B 62 PIEZAS MODELO MD100TBF 8 7 12 10 6 5 4 3 2 2 1 2 2 13 1 9 11 ...
Страница 64: ...www usaprocom com 200031 01B 64 PIEZAS MODELO MD200TBF 8 15 7 12 14 10 6 5 4 3 2 2 1 2 2 13 1 9 11 ...