www.factorybuysdirect.com
200308-01A
10
Figure 6 - Mounting Bracket Location
Figure 5 - Moving Thermostat Sensing
Bulb
INSTALLATION
Marking Screw Locations
1. Tape mounting bracket to wall where
heater will be located. Make sure mount-
ing bracket is level.
WARNING: Maintain mini-
mum clearances shown in Figure
4, page 9. If you can, provide
greater clearances from floor
and joining wall.
2.
Mark screw locations on wall (see Fig-
ure 7).
Note: Mark only last hole on each
end of mounting bracket. Insert mounting
screws through these holes only.
3. Remove tape and mounting bracket from
wall.
Bulb Clip
Thermostat
Sensing
Bulb
Mounting
Bracket
Mounting Bracket
The mounting bracket is located on back panel
of heater (see Figure 6). It has been taped
there for shipping. Remove mounting bracket
from back panel.
1. Pull out the sensing bulb from the two clips
located in the shipping position. There is
no need to take out the two bulb clips.
2. Take out the bulb clip from the hardware
package and insert it into the square hole.
Then insert the sensing bulb into the bulb
clip (see Figure 5).
FASTENING HEATER TO WALL
INSTALLING THERMOSTAT SENSING BULB (OPTIONAL)
FAN
HOT
11
1
/
10
"
Min.
16
1
/
16
"
12
3
/
4
"
Min.
Only Insert Mounting
Screws Through Last
Hole On Each End
Floor
Adjoining W
all
Figure 7 - Mounting Bracket Clearances
Methods For Attaching Mounting
Bracket To Wall
Use only the last hole on each end of mount-
ing bracket to attach bracket to wall. Attach
mounting bracket to a wall only in one of two
ways:
1.
Attaching to wall stud:
This method pro-
vides the strongest hold. Insert mounting
screws through mounting bracket and into
wall studs.
2.
Attaching to wall anchor:
This method
allows you to attach mounting bracket to
hollow walls (wall areas between studs)
or to solid walls (concrete or masonry).
Decide which method better suits your needs.
Either method will provide a secure hold for
the mounting bracket.