4.1.2 - CONVEYOR WITH “SLIDE”
Should the TM Vegetable cutter be supplied with a conveying slide,
position the same under the unloading opening
(Fig. n°18).
NB. For correct assembly:
Pass the screws through the holes of the slide pushing them down until
the slide is completely hooked in place.
4.2 - ELECTRICAL INSTALLATION
4.2.1 - T.M. MONOPHASE VEGETABLE CUTTER (220/230 Volt, 50 Hz)
The T.M. Vegetable cutter is supplied with an electrical lead of 3x1 mm²
Section; 1,5 m length, and with a ‘SHUKO’ plug.
Link the Vegetable cutter to a monophase 220/230 Volt 50 Hz network,
inserting a 10 A,
Δ
I = 0.03 A differential-magnetothermical switch.
Ensure that the earthing network is perfectly functional.
Fig. n°17 - Collecting device
with
tray
Fig. n°18 - Conveing accessory “slide”
SENSOR
PUS
H
ING
DIRECT
ION
16
C on the structure able to block the functioning of the machine should
the collecting tray or slide be incorrectly positioned at the unloading
opening, and that allows for the
volontary start
of the machine
(pushing the “I” button) only once the tray and slide are adequately
positioned.
Fig. n°4 - Position of the slide or tray to allow for ignition
Furthermore, the T.M. Vegetable cutter is endowed with a controlling
device made up of:
D an insulated IP 54 “O”
(Fig. n°5).
E an insulated IP 34 power card, made up of a transformer and two
homologated rays, run by a control box and by sensors positioned on
the tray, the slide and on the cover; able to switch the machine on and
off.
The T.M. Vegetable cutter allows for a N.V.R. device which, in case of
renewed tension after previous failure, allows for the machine to be
switched on exclusively by means of the START button “I”.
1.4 - ACCES UTENSILS
1.4.1 - ACCESSORIES
The T.M. Vegetable cutter is supplied with many accessories. Some are
supplied as standard accessories, others only upon specific request by the
Client.
Fig. n°5 - On - Off card
9