tion.

3 - Set the unit mixer/refrigeration switch of the bowl to

II position.

Note:

 when Autofill switch is set to position 0, the unit performs

as a standard unit not equipped with Autofill Device.

8. 2. 2 OPERATIONAL HELPFUL HINTS

1 - When the remote fill system is equipped with Sold-out

switches if a product sold-out occurs the Autofill Device
automatically stops and acoustic and visual alarms are
activated. Once product is restored, by keeping manually
pushed the Autofiil switch (located in the rear wall) in II
position, it is possible to manually reactivate the remote fill
system as already told in 3.1.

2 - The 1.25 Amps Fuse located near the terminal block has

the purpose to protect the Autofill Devices from short cir-
cuits or overloads on #1 and #2 poles.

3 - After cleaning and sanitizing procedures carefully dry the

bowl and the clip probe to avoid that the water present on
the bowl may be understood as level reaching the probe
and “causing of stopping of the refill”.

8. 2. 3 IN-PLACE SANITIZATION

T h e   I n - P l a c e   S a n i t i z a t i o n   o f   t h e   A u t o f i l l   s y s t e m   i s
recommended to guarantee the best product taste and the
highest unit efficiency. This section is a procedural guideline
only and is subject to the requirements of the local Health
Authorities.
Prior to perform the In-Place Sanitization the machine must be
emptied of product. To do this proceed as follows:

1 - Use a clean tank for each of the following:

a -Cleaning Tank - fill with warm (45-60 °C / 120 - 140 °F)

potable water.

b -Sanitizing Tank - fill with sanitizing solution (100 PPM

available chlorine concentration or 1 spoon of sodium
hypoclorite diluted with half a gallon of water) according
to your local Health  Codes and manufacturer’s
specifications.

2 - Repeat the following procedure on each of the unit bowls:

a -Disconnect the beverage source and in place of it

connect the Cleaning Tank to the remote fill system line.

b -Set the unit Power Switch to position I. Manually

energize the Autofill Device, by keeping pushed the
Autofill Switch (located on the rear cover of each bowl)
in position II, until the cleaning water flows free from any
beverage residue.
Set the unit Power Switch to position 0 and drain all the
liquid from the bowl.

c -Disconnect the Cleaning Tank and in place of it connect

the Sanitizing Tank to the remote fill system line.

d -Set the unit Power Switch to position I. Manually

energize the Autofill Device, by keeping pushed the
Autofill Switch (located on the rear cover of each bowl)
in position II, until sanitizing solution only outflows.
Flush at least a quarter of a gallon of sanitizing solution
to make sure that all the system has been filled with it.
Set the unit Power Switch to position 0 and drain from
the bowl all the sanitizing solution.

e -Disconnect the Sanitizing Tank and in place of it

connect the Beverage source to the remote fill system
line.

f -Set the unit Power Switch to position I. Manually

energize the Autofill Device, by keeping pushed the

Autofill Switch (located on the rear cover of each bowl)
in position II, until full strengh beverage outflows.
Set the unit Power Switch to position 0 and drain all the
liquid from the bowl.

g -Set the unit Power Switch to position I. Manually

energize the Autofill Device, by keeping pushed the
Autofill Switch (located on the rear cover of each bowl)
in position II, dispense a cup of beverage and check its
t a s t e .

h -If not satisfactory, drain all the liquid from the bowl and

repeat point G until obtaining a satisfactory tasting drink.

Note

: the above Autofill Syestem In Place Sanitization must be

followed by unit cleaning and sanitization as described in
standard unit Operator’s Manual.

8. 3 ROUTINE MAINTENANCE

Daily: 

inspect the machine for signs of product leaks past seals

and gaskets. If proper assembly does not stop leaks around
seals or gaskets, check for improper lubrication, worn or
damaged parts. Replace parts as needed.

-

set the Autofill switch to 0 position.

-

set the unit power switch to I position

-

set the unit mixer/refrigeration switch to I position (Soft
Drink mode)

-

place a pail under each faucet and drain all product from
bowls

-

set all control switches to 0 position

IMPORTANT

Weekly: inspect the contact between the clip probe
and the rear wall. Keep it clean and free from sugar or
dust

Содержание MT-2-ULAF

Страница 1: ...ENGLISH MHV 2 UL AF O P E R A T O R S M A N U A L ...

Страница 2: ......

Страница 3: ...EDURES 5 5 1 DESCRIPTION OF CONTROLS 5 5 2 OPERATION HELPFUL HINTS 6 5 3 CLEANING AND SANITIZING PROCEDURES 6 5 3 1 DISASSEMBLY 6 5 3 2 CLEANING 7 5 3 3 SANITIZING 8 5 3 4 ASSEMBLY 8 5 4 IN PLACE SANITIZATION 8 6 ROUTINE MAINTENANCE 9 6 1 MAINTENANCE TO BE CARRIED OUT BY QUALIFIED SERVICE PERSONNEL ONLY 9 7 DEFROST TIMER 9 8 AUTOFILL SYSTEM 9 8 1 INSTALLATION 10 8 2 OPERATING PROCEDURES 10 8 2 1 D...

Страница 4: ...chapter 5 3 CLEANING AND SANITAZING PROCEDURES 4 TO OPERATE SAFELY 1 Do not operate the dispenser without reading this opera tor s manual 2 Do not operate the dispenser unless it is properly groun ded 3 Do not use extension cords to connect the dispenser 4 Do not operate the dispenser unless all panels are restrai ned with screws 5 Do not obstruct air intake and discharge openings 15 cm 6 minimum ...

Страница 5: ...hting of the warning light at the left of the switch covers means insufficient ventilation of the unit In this case check that all around the dispenser there is sufficient space for ventilation at least 15 cm 6 on each side and that condenser filter is free from dust or other obstructions In case the warning light is still ON even after these operations have been carried out Service call is requir...

Страница 6: ...ixers may be restarted only after product is melted 8 The dispenser is equipped with a magnetic coupling by which the gear motor located outside the bowl drives the mixers inside the bowl The magnetic drive operates as an intelligent clutch able to automatically disconnect the mixers in case they are seized by ice or other causes This inconvenience can be soon noticed since an intermit tent dull n...

Страница 7: ...uitable for the purpose thoroughly clean all disassembled parts in the cleaning solution 3 Do not immerse the lighted top covers in liquid Wash them apart with the cleaning solution Carefully clean their undersides 4 In the same manner clean the evaporator cylinder s using a soft bristle brush 5 Rinse all cleaned parts with cool clean water ATTENTION Before any disassembly and or cleaning procedur...

Страница 8: ...e faucet by reversing the disassembly steps see figure 10 4 Fit bowl gasket around its seat see figure 9 Note the largest brim of gasket must face against the rear wall see figure 12 figure 12 5 Insert the auger into the evaporator taking care to accom pany it to the end so as to prevent it from hitting against the rear wall see figure 13 figure 13 6 Install the outer spiral Slide it over the evap...

Страница 9: ... and the opposite This means that during defrost periods frozen Granita will melt to thermostat setting temperature and once defrost period has expired the product automatically freezes down again to Granita setting viscosity figure 16 To operate the defrost timer proceed as follows see figure 16 Set the time of the day by rotating the dial clockwise arrow A Never rotate the timer counterclockwise...

Страница 10: ...gets uncovered because of dispensed product the solenoid valve inside the rear wall automatically opens and fresh beverage flows into the bowl until the probe tip gets covered again The solenoid valve opening occurs with about 10 seconds delay to avoid that the irregular waving of product surface occasionally discovering probe tip may be understood as level dropping cause of dispensing A sold out ...

Страница 11: ... rear cover of each bowl in position II until the cleaning water flows free from any beverage residue Set the unit Power Switch to position 0 and drain all the liquid from the bowl c Disconnect the Cleaning Tank and in place of it connect the Sanitizing Tank to the remote fill system line d Set the unit Power Switch to position I Manually energize the Autofill Device by keeping pushed the Autofill...

Страница 12: ...SPARE PARTS LIST MHV 2 UL AF 2430_49 V 2 8 07D11 ...

Страница 13: ...41 10028 02804 Flange OR 3231 69 22800 22202 Rear cover fixing screw 13 22800 16102 Outer spiral 42 22800 15370 Gear motor flange 72 10028 00905 Condenser filter 14 22800 16502 Switch box 43 21299 00000 Delay electronic device PWB made to 09 2001 73 10028 03307 Panel fixing screw 15 22800 16402 Power switch box 43 22800 05240 Delay electronic device PWB made from 09 2001 77 10028 02002 Timer cover...

Страница 14: ...ar 22 22800 22602 Rotor 4 10028 03201 Washer 13 22800 22650 Fourth gear 23 22800 22634 Pinion 5 10028 03200 Rotor spacer 14 10028 03203 3 3 mm spacer 24 10028 03204 Bushing 6 33800 03802 Gear box with bushing 15 10028 03215 Bushing rubber cap 25 10028 03205 Washer 7 22800 22615 Seal retainer 17 22800 22639 First gear 26 10540 13532 Bracket screw 8 10028 03216 Ball bearing 28 mm rubber cap 18 22800...

Страница 15: ... 22800 24609 Spring 11 10028 03212 Faucet OR 12 22800 24607 Faucet front part 13 33800 09100 Faucet gasket 14 22800 24608 Faucet rear part 15 10028 01300 Fitting locker 16 22040 00000 Fitting OR 17 00222 02345 Bent 1 4 fitting 18 10028 01402 Led light gasket 19 10028 00401 1 25 Amps 250 V fuse 6 3x32mm 20 10028 00300 Fuse holder 21 10028 01404 Terminal block 22 22800 00003 MHV 2 AF back panel 23 2...

Страница 16: ...CECILWARE CORPORATION 43 05 20th Avenue Long Island City N Y 11105 Tel 800 935 2211 Fax 718 932 7860 Email cecilware aol com www cecilware com 2430_49 R2 9 07D11 ...

Отзывы: