Operation (continued)

NOTICE: 

Clean and sanitize unit before first use. See

following section, 

Cleaning

.

Tea Brewing Instructions

1. Start each brew cycle with a clean brew funnel and

a clean empty tea dispenser.

2. Place a tea bag into the funnel and slide the funnel

into the funnel rails until it stops.

3. When the Green Brew Switch Light comes on, press

and release the Brew Button.

NOTICE:

This tea brewer will not brew until the pre-

set brew temperature (197-203° F) is reached.

4. Allow approximately 3 minutes for the tea

concentrate to stop dripping from the Funnel tip.

5. Carefully remove Brew Funnel and discard the used

tea bag ONLY AFTER all visible dripping has
stopped.

FLAVOR CHART

Cleaning

NOTICE: 

Do not use scouring cleaners on the urn’s

surfaces. When cleaning stainless steel, only a ph
neutral cleaner should be used. Use nylon or plastic
brushes (not steel wire brushes) for removing food
deposit.

Cleaning and Sanitizing Instructions
After Each Brew:

1. Dispose of grounds and rinse brew basket.
2. Rinse dispenser before reuse.

Daily:

Clean and sanitize your tea brewer and

dispenser at least 

once every 24 hours

.

1.  Remove and disassemble the faucet assembly by

unscrewing. Carefully inspect washers. Replace any
damaged parts.

2.  Place brew funnel, cover, drip tray cover, and faucet

components into a warm soapy wash.

3.  Clean all components by brushing or scrubbing. Use

a bottle brush to wash faucet and faucet mounting
location. Wash inside of dispenser.

4.  Wipe exterior surfaces. Use only a soft cloth and

warm soapy water or stainless steel polish on the
outside to avoid scratches.

5.  Rinse carefully to remove soap.
6. Prepare a sanitizing solution in accordance with

local health department regulations. You may also
refer to the US Food and Drug Administration
regulation 21 CFR 178.1010 “Sanitizing Solutions”
and US Environmental Protection Agency 40 CFR
18.940 “Tolerance exemptions for active and inert
ingredients for use in antimicrobial formulations
(Food-contact surface sanitizing solutions)”.

7. Follow the instructions provided with the sanitizing

agent.

8. Let all sanitized parts drain and dry naturally. DO

NOT WIPE THEM DRY.

9.  Reassemble brewer and dispenser.

Type of

Tea

Hot Water

Brewing

Concentrate

Cold Water

Dilution

Tea

Bag

Size

Total

Brew

Time

Unsweet

0.75 gal. (96

oz)  in 3
minutes

2.25 gal.

(288 oz)

3 oz

6.0 min

Sweet

0.70 gal. (90

oz)  in 3
minutes

2.00 gal.

(256 oz)

3 oz

5.5 min.

CAUTION: 

Burn hazard. Water used for

brewing tea is very hot. Use caution when brewing,
pouring, or transporting hot tea. Never attempt to
move the urn without first draining or allowing
contents to cool.

Содержание B-1/3

Страница 1: ...eration 4 Cleaning 5 Maintenance 6 Troubleshooting Guide 9 Parts Diagram and List 10 Wiring Diagram 14 Thank you for purchasing this quality tea brewer or dispenser For your safety and the safety of o...

Страница 2: ...Do not use near combustibles Use only on a circuit load that is properly protected and capable of the rated load Always unplug unit from power supply before servicing or cleaning If the main power su...

Страница 3: ...trical TB3 Brewer with B1 3T Dispenser Tea Brewer with Dispenser 3 gallon capacity C UL US NSF Certification 1 4 water line required 120V 1 8 kW 15A 1 Ph Line cord included NEMA plug 5 15P B1 3 Dispen...

Страница 4: ...all the water inlet fitting provided onto the inlet valve located in the back of the unit Do not over tighten 3 Connect a 1 4 copper waterline to the 1 4 flare water inlet fitting of the valve INITIAL...

Страница 5: ...g Carefully inspect washers Replace any damaged parts 2 Place brew funnel cover drip tray cover and faucet components into a warm soapy wash 3 Clean all components by brushing or scrubbing Use a bottl...

Страница 6: ...TEA and then adjust the Timer to 3 to 5 min depending on the water pressure in the main water line COLD WATER DILUTION DELAY TIMER ADJUSTMENT located inside the unit near the water inlet valve Set De...

Страница 7: ...reading and repeat if necessary To DECREASE the water temperature simply turn the Thermostat Knob one notch counterclockwise CCW to the next lower dial setting CRITICAL COMPONENTS TESTS A Water Inlet...

Страница 8: ...e Water Level Control Board Test Check the board as follows 1 Make sure there is power input to the board at the terminals 2 3 Your voltmeter should read 115 Volts It should read the same at terminals...

Страница 9: ...if necessary at all or no water is coming See Water Inlet Valve Test from dilution nozzle Hi Level Float Switch malfunction Test High Level Float Switch Replace if necessary Probe malfunction Check P...

Страница 10: ...authorization must be obtained from Grindmaster Cecilware for all warranty claims Grindmaster Cecilware provides the industry s BEST warranty Visit our website at GMCW com for warranty terms and condi...

Страница 11: ...LACK COVER MOLDED 3 GAL OCTAGON BASE M028AL P264A M776AL Q181AL 3 GAL M632AL 2 P015AL 2 D064EL 355 00025 19015L 2 359 00092 RT31AL RT33QL CECILWARE CHROME LABEL 380 00061 PINCH FAUCET D084AL M776QL CO...

Страница 12: ...RV33QL HOSE WATER INLET 24 M326AL 6 WATER INLET VALVE CD241L QTY 5 6 15 DUAL LEVEL CONTROL BOARD 17 RELAY TEMPERATURE LOCK OUT L539AL TEA BREWER TB 3 16 17 OVERFLOW HOSE M545AL 18 BREW HOSE M326AL CEC...

Страница 13: ...TB Series Iced Tea Brewer Cecilware 13 Parts Diagram and List continued HOT WATER TANK Part No RV33C 2 0 Gal 2 4 5 6 8 7 1 10 9 12 3 11...

Страница 14: ...14 Cecilware TB Series Iced Tea Brewer Wiring Diagram...

Страница 15: ...TB Series Iced Tea Brewer Cecilware 15...

Страница 16: ...lware 4003 Collins Lane Louisville KY 40245 USA Phone 502 425 4776 Toll Free 800 695 4500 Fax 502 425 4664 Web gmcw com Email info gmcw com 2008 Grindmaster Cecilware Printed in USA 0915 Form CW 313 0...

Отзывы: