![Cebora BRAVO MIG 574 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/cebora/bravo-mig-574/bravo-mig-574_service-manual_2577450020.webp)
CEBORA S.p.A.
20
3.302.155
22/01/04
5.3
- Control board (42) code 5.602.151.
5.3.1
- Topographical drawing.
5.3.2
- Connector table.
Conn. Terminals
Function.
J1
1 - 2
28 Vac input for control board (42) power supply.
J1
3 - 5
solenoid valve (14) command output.
J1
4 - 6
contactor (47) command output.
J1
7 - 8
input signal from safety circuits (thermostat (63) and wire feeder unit guard switch (59)).
J1
9 - 10
start signal input from torch button.
J2
1(+) - 2(-)
wire feeder motor (5) command output.