background image

3

BATTERY CHANGE.

OTHER APPLICATIONS.

OUTPUTS CONNECTION. LOAD.

4

CHANGE AND INFORMATION 

: When the you stop to supply the module, 

the module maintain the timer thanks to a battery. Manual and automatic 
relays' activation as well as hour visualisation will be cancelled till you supply 
again the module.. This battery will be discharged according to its use. If 
you do not change the battery, the module could not recuperate the hour 
if its supplying is stopped. 
The required battery is a CR-2032 with 3 V. that you could obtain in 
specialised distributors. 
To change it you have to carefully respect its polarity seeing the drawing. 
Do not change the battery with the module supplied.

MINUTE'S SIGNAL 

: The I-53 module is an automatism to activate hours and others outputs with an other output 

for minute signals. This signal is detected each time minutes change offering during 0,5 sec. an impulse with a 
high level. Do not connect any devise at this output, except the suggest devise hereafter. If you do not respect 
this point you could seriously damage the module and cancel the module's guarantee. Please proceed as 
followingÊ: 
To obtain a relay output generating a minute signal, you have to find a 12 V relay and a 1 N4148 diode.
Seeing the following electrical and physics maps you have to connect "C" terminal of the JP1 jumper with the 
indicated point. Do the same operation with the "E" terminal. Connect negative and positive terminals to the 
module's input voltage. Be careful with the polarity.

I-53

I-53

TIMERS

I-53

I-53

Ref. Full9809

TIMER FOR CLOCK AND BELL.

2

C

R

03

2

V.

R

BA

TE

Y

1

ON

2

1

ON

2

INT-2

INT-1

Battery

1N 4148

Positive of the module

Negative of the module

JP1

1N 4148

12 V. Relay

12 V. Relay

Positive of the module

ELECTRICAL SCHEDULE.

Negative of the module

NO

NC

Common

C

E

JP1

E

C

PHYSICAL SCHEDULE.

All the module’s CEBEK have 

3 years of total warranty 

in thecnical 

repairing, and spares from the date of buy.

CEBEK is trade make of FADISEL S.L. more than 300 module’s are avaible in 
stock for any purpose 

request our CATALOGUE, 

or visit our Web.

 

Http://www.cebek.com

TECHNICAL CONSULTATIONS.

If you have any doubt, you could contact your wholesaler or our Technical  Department.
- Via E-Mail,  

[email protected]     |    

by mail

 

 P.O Box 23455 08080 BARCELONA - SPAIN

Keep the invoice of this module

. For any repair, the corresponding invoice had to be added. If the invoice is 

not presented together with this module, the module’s warranty will be automatically cancelled. 

GENERAL WIRING MAP.

Outputs Connection 

: The I-53 output is controlled by a relay, and accept any devise up to 3 A. The relay 

have three output terminals : The normally open quiescent (NO), the normally closed quiescent (NC) and 
the common. This mechanism operate like a switch with two terminals NO and Common. For the inverse 
function you have to use the NC and Common. In the drawing hereafter, you could see a typical 
connection with a 12 V D.C and 230 V A.C devises. 

R2

03

C

2

3

V

  .

BA

TER

Y

1

O

N

2

1

O

N

2

Others Relay

Hours Relay

INT-3

Batter y

JP1

C

E

INT-2

INT-1

1

O

N

OUTPUTS CONNECTION. LOAD.

230 V AC. CONNECTION

12 V DC CONNECTION

12 V. DC.

Common

Common

(NO) Normally Open

(NO) Normally Open

(NC) Normally Closed

(NC) Normally Closed

Device,

Load.

Device,

Load.

230 V. AC.

DO NOT FORGET 

: When the circuit works, and according to the load you could note a fluctuation or incorrect 

operating on the output. If it is the 
case, you have to connect a circuit 
(composed by resistor and capacitor) 
between both contacts of the relay 
(see the schedule herewith). 

Common

(NO) Normally Open

(NC) Normally Closed

Device,

Load.

100nF/400 V.

47

W

 1/2W.

Load’s power supply.

Module

I-53

Power Supply

NO

NO

NC

NC

Common

Common

Hours

Outpout

Others

Output

230 V. AC. Mains

Mains

Switch.

250 mA.

Fuse

Led

Module

FE-2

TRANSFORMER.

FE-2

0

0

15

230

E L E C T R O N I C C I R C U I T S

 

Y

S

E R

A

Содержание I-53

Страница 1: ...tive terminal indicated in the wiring map then connect also the negative of the power supply to the negative terminal indicated in the circuit Verify that the assembly has been correctly done OPERATING The I 53 module is an automatism to imitate the operating Bell clock indicating hours and others Then the hour relay will be activated each hour and the second relay will be activated each 15 minute...

Страница 2: ...ween 8 00 A M and 22 P M If you place it in ON position the margin will established between 6 00 A M and 24 Hours MANUAL CONTROL In spite of the automatic operating mode and independently the I 53 module allows at any time to establish a manual connection for hours and others To activate this operation you have to maintain pressed the button corresponding to the manual control TO ACTIVATE BOTH OUT...

Страница 3: ...iously damage the module and cancel the module s guarantee Please proceed as followingÊ To obtain a relay output generating a minute signal you have to find a 12 V relay and a 1 N4148 diode Seeing the following electrical and physics maps you have to connect C terminal of the JP1 jumper with the indicated point Do the same operation with the E terminal Connect negative and positive terminals to th...

Страница 4: ...ly cancelled GENERAL WIRING MAP R203 C 2 3 V BATERY 1 ON 2 1 ON 2 Others Relay Hours Relay INT 3 Battery JP1 C E INT 2 INT 1 1 ON OUTPUTS CONNECTION LOAD 230 V AC CONNECTION 12 V DC CONNECTION 12 V DC Common Common NO Normally Open NO Normally Open NC Normally Closed NC Normally Closed Device Load Device Load 230 V AC DO NOT FORGET When the circuit works and according to the load you could note a ...

Отзывы: