background image

I-210

To exit the working screen, hold for 2 seconds. Pause key. If the program does not contain a signal "End"or "End *", you 

must create one to get out. If the modification of a program a sequence that overlaps and exceeds by length of which 

reflected the end of the program (signal "End" or "End * ") must indicate a new end of program. 

CONFIRMATION TICKETS OR STOP. 

The form I-210 incorporates an input "External"for each relay. Each of these 

inputs act on the agenda of the corresponding relay. In those sequences where the state program's output was set to "Ex", 

the module to reach them and as lasting, continual check the entry. If the input is in contact with the common, the relay will 

connect, if on the contrary, the entrance was open, the relay is disconnected. Observe the General Wiring.

PERFORMANCE OF WORK.

 Working Screen (Fig. 1, p. 2), is the main module, this display shows the current status 

at any time the status of each output, displaying under the names of each relay (RE1 or Re2), the exact mode of output, 

On, Off, or Ex .

Keys either Relay 1 or Relay 2, when pressed activate all prerecorded programs, initiating the operation of the 
module. 

The Pause key, as its name suggests, will pause to freeze the program in the step that was pressed, restoring the system 

to again be pressed. 

Enter button, hold no combination with another key, will perform a program stop, "Stop", leaving the circuit waiting for a 

new start. 

RUNPauseStop<" onmouseout="this.style.backgroundColor='#fff'"Working Screen indicate at any time if the program is 

running, if it is paused or if it is stopped, correspondingly displaying the following message:> RUN <""> Pause <"and"> 

Stop < ". 

Likewise, the display will continuously step in which the program is showing the message "No STEP", where "No" will 

counter the current step. 

Note that not all programs have the same length or duration. Therefore, although the module will execute at the same 

time, shorter, are off, pending the end of the major. This point should be especially taken into account, if any of the 

software was cyclical, and then, after completion of the longest, and having concluded its function the remaining, only the 

cyclic restarts, continuing his work indefinitely until making a "Stop".

CONNECTION OF OUTLETS. LOAD.

 The outputs of the I-210 is performed by relays, devices that support any type 

of load does not exceed 5 A. The relay has three output terminals. The rest normally open (NO), the Sleep normally closed 

(NC) and the Joint Operation of this mechanism is identical to a switch whose two terminals NA and the common to the 

inverse function must be used and common terminal CN is shown in Figure The typical connection for a device operated 

at 12 V. S.C. and one operated at 230 V. C.A. See paragraph Connecting the charges.

ABOUT THE OUTPUT.

 During operation of the circuit, and according to its load, it could happen a fluctuation or an 

incorrect output performance. If this happens, install a circuit sparking between the two relay contacts used in this connection, 

as shown in the drawing.

5

www.cebek.com

    -    [email protected]

Содержание I-210

Страница 1: ...ll allow the grouping and configuration steps outlined in chart form the pattern of desired operation for each output Keeps in memory the programs carried out even after power off Includes display relay status LED connection indicators and terminals for wiring POWER SUPPLY The I 210 must be supplied with a voltage of 12 V S C Adequately stabilized so we suggest not using simple power supply advers...

Страница 2: ...llest measure Describe later how to assign a measure of real time to the division step The graph is made by grouping steps Returning to the example above the circuit should be scheduled first grouping step 0 to 4 which will be configured connection in step 4 to 12 in the disengagement from 12 to 22 in connection and finally from 22 to 34 in disconnection Finally assigned as a measure of time per s...

Страница 3: ...led in Confirmation Check or Stop To move the cursor to the State of Exit press Pause Each press on this key cyclically rotate the location of the cursor between indicators of Sequence Step and output status Stand on the indicator of state of the output Using the Up and Down keys to select one of the three output state Select the ON state After composing the sequence and assign an output state the...

Страница 4: ...d or the minute cycle press the Pause key To change the value of any of them use the Up or Down Once the change is made press the Enter key and the module will record the new reference time returning to the work screen Remember that the minimum working time is 5 tenths If you select a time below but the display screen the module will automatically record the minimum allowed 0 5 sec Moreover time p...

Страница 5: ...top onmouseout this style backgroundColor fff Working Screen indicate at any time if the program is running if it is paused or if it is stopped correspondingly displaying the following message RUN Pause and Stop Likewise the display will continuously step in which the program is showing the message No STEP where No will counter the current step Note that not all programs have the same length or du...

Страница 6: ...I 210 GENERAL WIRING MAP I 210 Relay 1 Relay 2 Entry alimentation Entries confirmation Output 1 Output 2 Comm on Inpu t 1 Input 2 www cebek com sat cebek com ...

Отзывы: