I-210

PROGRAMMING 

The I-210 is a PLC, a module which you can set a full schedule operation for each output. The circuit 

also thanks to its programming step by step, we will set up a flexible graphical performance. They usually present needs 

work on different devices, on which asynchronous operation is required and complex. Hard work applicable patterns with 

simple timers. These devices typically require such cycles capricious eg, 4 sec. connection, immediately after 8 sec. off, 

after which 7 sec. of connection, then again 12 sec. disconnect, etc. These "Guidelines for Operation" can be easily 

programmed through the I-210. The module, however, instead of having a standard measure by which to make the graph, 

for example, sec., as ilustrábamos above, the circuit employs "steps", this being its smallest measure. Describe later how 

to assign a measure of real time to the division step. The graph is made by grouping steps. Returning to the example 

​​

above, the circuit should be scheduled first grouping step 0 to 4, which will be configured "connection" in step 4 to 12 in 

the "disengagement" from 12 to 22 in "connection", and finally from 22 to 34 in disconnection. Finally, assigned as a 

measure of time per step, 1 sec. See Fig. 1

Figure 1 - Sample performance graph

Common Graphic

Graph in step

Sequence 1

Sequence 2

Sequence 3

Sequence 4

Programming the I-210 is similar to that used in home videos. Using the buttons and display panel embodying the control 

module will perform all functions. See Fig 2. Power feeding module. The display will briefly describe the module, and 

following her visualize the data shown in Fig. 2.

Figure 2 - Front view of the control lever of I-210.

Working screen

Display screen

Up key

Key Down

Among key

Key relay 1

Key relay 2 Pause key

2

www.cebek.com

    -    [email protected]

Содержание I-210

Страница 1: ...ll allow the grouping and configuration steps outlined in chart form the pattern of desired operation for each output Keeps in memory the programs carried out even after power off Includes display relay status LED connection indicators and terminals for wiring POWER SUPPLY The I 210 must be supplied with a voltage of 12 V S C Adequately stabilized so we suggest not using simple power supply advers...

Страница 2: ...llest measure Describe later how to assign a measure of real time to the division step The graph is made by grouping steps Returning to the example above the circuit should be scheduled first grouping step 0 to 4 which will be configured connection in step 4 to 12 in the disengagement from 12 to 22 in connection and finally from 22 to 34 in disconnection Finally assigned as a measure of time per s...

Страница 3: ...led in Confirmation Check or Stop To move the cursor to the State of Exit press Pause Each press on this key cyclically rotate the location of the cursor between indicators of Sequence Step and output status Stand on the indicator of state of the output Using the Up and Down keys to select one of the three output state Select the ON state After composing the sequence and assign an output state the...

Страница 4: ...d or the minute cycle press the Pause key To change the value of any of them use the Up or Down Once the change is made press the Enter key and the module will record the new reference time returning to the work screen Remember that the minimum working time is 5 tenths If you select a time below but the display screen the module will automatically record the minimum allowed 0 5 sec Moreover time p...

Страница 5: ...top onmouseout this style backgroundColor fff Working Screen indicate at any time if the program is running if it is paused or if it is stopped correspondingly displaying the following message RUN Pause and Stop Likewise the display will continuously step in which the program is showing the message No STEP where No will counter the current step Note that not all programs have the same length or du...

Страница 6: ...I 210 GENERAL WIRING MAP I 210 Relay 1 Relay 2 Entry alimentation Entries confirmation Output 1 Output 2 Comm on Inpu t 1 Input 2 www cebek com sat cebek com ...

Отзывы: