13
L11
-
L21
1
st
LEVEL PEAK CURRENT I
1p
2200 AC/DC
3000 AC/DC
5 ÷ 220 A
5 ÷ 300 A
L19
2
nd
LEVEL PEAK CURRENT I
2p
2200 AC/DC
3000 AC/DC
5 ÷ 220 A
5 ÷ 300 A
L20
1
st
LEVEL BASE CURRENT I
1b
2200 AC/DC
3000 AC/DC
5 ÷ 220 A
5 ÷ 300 A
L23
PULSATION FREQUENCY f
2200 AC/DC - 3000 AC/DC
FAST
0,5 ÷ 500 Hz
To exit the setting phase, hold the WELDING PARAMETERS SE-
LECTION key (T10) down for about
1 second
.
3C - ULTRA FAST PULSE + CYCLE
Press the PULSE key (T5) until the requited
pulsation is active (ULTRA FAST LED flashing).
Press the WELDING MODE SELECTION key
(T9) until the CYCLE welding mode is active
(CYCLE LED on).
Press the WELDING PARAMETERS SELEC-
TION Key (T10) a number of times to set the following (in addi-
tion to the WELDING PARAMETERS defined as being “BASIC”):
L11 L19 L20
L21
L23
T10
L11
-
L21
1
st
LEVEL PEAK CURRENT I
1p
2200 AC/DC
3000 AC/DC
5 ÷ 220 A
5 ÷ 300 A
L19
2
nd
LEVEL PEAK CURRENT I
2p
2200 AC/DC
3000 AC/DC
25 ÷ 220 A
25 ÷ 300 A
L20
1
st
LEVEL BASE CURRENT I
1b
2200 AC/DC
3000 AC/DC
5 ÷ 220 A
5 ÷ 300 A
L23
PULSATION FREQUENCY f
2200 AC/DC - 3000 AC/DC
ULTRA FAST
500 ÷ 2000 Hz
To exit the setting phase, hold the WELDING PARAMETERS SE-
LECTION key (T10) down for about
1 second
.
PULSE
SYN
FAST
SLOW
T5
T9
3D - SYN PULSE + CYCLE
Press the PULSE key (T5) until the requited
pulsation is active (SYN LED on).
Press the WELDING MODE SELECTION key
(T9) until the CYCLE welding mode is active
(CYCLE LED on).
Press the WELDING PARAMETERS SELEC-
TION Key (T10) a number of times to set the
following (in addition to the WELDING PARAM-
ETERS defined as being “BASIC”):
L11 L19
L22
T10
L11
-
L21
1
st
LEVEL PEAK CURRENT I
1p
2200 AC/DC
3000 AC/DC
25 ÷ 220 A
25 ÷ 300 A
WARNING: When the SYN PULSE function is active, the 1
st
level
PEAK CURRENT (
I
1p
) is regulated to achieve a synergy with the
values for the other 1
st
level parameters (
I
1b
,
f ).
L19
2
nd
LEVEL PEAK CURRENT I
2p
2200 AC/DC
3000 AC/DC
5 ÷ 220 A
5 ÷ 300 A
WARNING: When the SYN PULSE function is active, the 2
nd
level
PEAK CURRENT (
I
2p
) is regulated to achieve a synergy with the
values for the other 2
nd
level parameters (
I
2b
,
f ).
If you want to do a test weld, during the test the LED for the pa-
rameter selected flashes and the DISPLAY shows the value for the
parameter you are setting.
To exit the setting phase, hold the WELDING PARAMETERS SE-
LECTION key (T10) down for about
1 second
.
NOTE: During the welding process if LED I
p
and LED
I
1
stay
switched on on the DISPLAY, the 1
st
level current at which you
are welding is displayed.
NOTE: During the welding process if LED I
2
and LED
I
p
stay
switched on on the DISPLAY, the 2
nd
level current at which you
are welding is displayed.
SPECIAL CONFIGURATION (SPE)
In welding processes:
• TIG AC with HF ignition
• TIG DC with HF ignition
The
MATRIX AC/DC
makes it possible to activate modification of
some WELDING PARAMETERS therefore providing a more ex-
pert welder with a more versatile welding machine.
Activation will only take place after the machine configuration is
changed from STANDARD (Std) to SPECIAL (SPE), which must
be done as follows:
1) When the welding machine is off, push and hold the “PRG”
PROGRAM key down (T2).
2) Start the welding machine by turning the power supply switch
to position
I
.
3) The DISPLAY (D) shows the following message:
Std
(welder
configured in STANDARD mode).
PULSE
SYN
FAST
SLOW
T5
T9