VIII. Troubleshooting
Case
Cause
Solution
No Heat in the Tunnel
No Power
Turn On Power
Heating Switch Broken
Replace
AC Contactor, Solid-
booster
or
temperature meter is
broken
Replace or Repair
Heat adjustment is in
the lowest position
Adjust
Temperature of Tunnel
is Low
Some heating pipes
broken
Replace
Heat adjustment is too
low
Increase
Temperature is set too
low
Reset
One of the 3 fire wires
is loose
Re-Connect
Conveyor Motor Stops
Running
Switch
or
Adjuster
Broken
Replace
The motor burned
Replace
Carry Adjustments is in
the Lower position
Adjust
Block on the driving
unit
Adjust / Mend
Motor of fan not
working
Fan Switch Broken
Replace
Fan Motor Broken
Replace
Circuitry broken
Mend
Stop suddenly
Power loose or fuse
pipe broken
Replace