![CDVI SOLARMBD Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/cdvi/solarmbd/solarmbd_installation-manual_2576837006.webp)
6
cdvigroup.com
30-bit Wiegand Output
Signals output in open collectors with pull up in 30-bit hexadecimal format. The output format
from the proximity reader is 30-bit wiegand (Signal: DATA1, DATA0 and CLOCK) and is structured as follow:
1 - First parity:
1 bit – even parity for the fi rst 14-bit
Code: A code is formed from 7 half byte.
Each byte is transferred from bit 7 to bit 0.
2 - Second parity:
odd parity for the last 14-bit.
Bit 1
Bit 2 to bit 29
Bit 30
Even Parity from bit 2 to bit 15
Data (28-bit)
Odd Parity from bit 16 to bit 29
Exemple A:
Temic card decimal code: 689905 (in hexadecimal: A86F1).
1
0000
0000
1010
0110
0110
1111
0001
0
Parity 1
0
0
A
8
6
F
1
Parity 2
The code number of the card is 00A86F1 in hexadecimal.
Exemple B:
EM badge hexadecimal code: 0100166A37.
1
0000
0000
0001
0001
0110
1011
0110
1
Parity 1
0
0
6
6
A
3
7
Parity 2
The code transmitted is in hexadecimal format 0166A37.
Parity 1:
0 if the number of 1 in bit 2 to bit 15 is even,
1 if the number of 1 in bit 2 to bit 15 is odd,
Parity 2:
0 if the number of 1 in bit 16 to bit 29 is odd,
1 if the number of 1 in bit 16 to bit 29 is even.
44-bit Wiegand Format Output
44-bit hexadecimal format. The output format from the proximity reader is 44-bit (Signal: DATA1, DATA0 and CLOCK)
and is structured as follow:
Data:
10 digit code number hexadecimal MSByte fi rst.
Each hexadecimal digit = 4 bit, MSBit fi rst.
LRC:
4 bit = OR restricted in between the digit of the data, MSBit fi rst.
Bit 1 to bit 40
Bit 41 to bit 44
Data MSBit fi rst
LRC
Exemple A:
EM badge hexadecimal code: 01001950C3.
0000
0000
0000
0000
0001
1001
0101
0000
1100
0011
0011
0
1
0
0
1
9
5
0
C
3
3
The code number of the card is: 01001950C3 in hexadecimal code.
EN
SOLARMWD - SOLARMBD
13.56Mhz EV1 Desfi re Mifare
®
Reader - Wiegand
INSTALLATION MANUAL