2-door Control Unit
7.1 With the control panel
7.1.1 Control panel overview
7] INTERLOCK MANAGEMENT
This product is delivered with a varistor.
The varistor must be connected directly to the locking system terminals
(electric strikes, electromagnet, or lock) operated by the device. If the device
functions with several locking systems, each one must be fitted with a varistor.
The varistor limits overload produced by the strike coil, known as self-effect.
If you are using a “Shear Lock” type of electric strike, electromagnet or lock,
we recommend the use of a separate power supply to the one used by the SASIC.