EN
SASIC
2-door Control Unit
TRAFFIC LIGHT INDICATOR BOARD
5 screw terminal block: Traffic light indicator*
Blocks
Description
1
0V input voltage
2
Red light (closed status)
3
Green light (open status)
4
Push button (call or automatic opening)
5
Buzzer
SAS CARD
Blocks
Description
1 > 5 screw terminal block: Traffic light indicator 1 (door 1 = exterior) IN
36
Green light (output)
35
Red light (output)
34
Buzzer (output)
33
0V Input voltage
32
Push button (input) > Call or automatic opening
1 > 5 screw terminal block: Traffic light indicator 1 (door 2 = exterior) OUT
31
Green light (output)
30
Red light (output)
29
Buzzer (output)
28
0V Input voltage
27
Push button (input) > Call or automatic opening
2 > 5 screw terminal block: Traffic light indicator 3 (door 2 = interior) IN
1
Green light (output)
2
Red light (output)
3
Buzzer (output)
4
0V Input voltage
5
Push button (input) > Call or automatic opening
2 > 5 screw terminal block: Traffic light indicator 4 (door 2 = interior) OUT
6
Green light (output)
7
Red light (output)
8
Buzzer (output)
9
0V Input voltage
10
Push button (input) > Call or automatic opening
1 > 8 screw terminal block: Exterior Lock A
44
Exterior card reader 1 / door open, normally open
43
Alarm (Position)
42
Door status
41
0V input voltage
40
+12V (Ouput)
39
39 NC (relay contact or +12V if ST2 in 1 and 2)
38
C (common relay)
37
NO (contact relay)
2 > 8 screw terminal block: Interior Lock B
11
Exterior card reader 2 / door open, normally open
12
Alarm (Position)
13
Door status
14
0V input voltage
15
+12V (Output)
16
16 NC (relay contact or +12V if ST3 in 1 and 2)
17
C (common relay)
18
NO (contact relay)
3 screw terminal block: RF Aerial (for a remote connection)
1
2
Not used
3
Aerial – coaxial wire shielding
ALARM > Bornier 3 points : Relais alarme
NO
Normally open
C
Common
NC
Normally closed
SAS CARD
Blocks
Description
TAMPER > Bornier 3 points : Contact fermé au repos / Alarme à l’ouverture
1
(shirt-cut with 3 if not used)
2
Not used
3
Tamper -
8 screw terminal block : Alarm, Emergency, Locking, Opening
19
Alarm + (contact normally open / Alarm on closing)
20
Alarm -
21
Eme (contact normally open / momentary closing triggers alarm
and opens)
22
Emergency -
23
L (contact normally open / Locks on closing)
24
Locking -
25
O (contact normally open / Opens the two doors on closing)
26
Opening -
5 screw terminal block: RS485
A
A (for the RS485 bus link to control panels and PC interfaces)
B
B (for the RS485 bus link to control panels and PC interfaces)
M
M (RS485 cable shielding)
-
0V (output voltage 0V for control panels and PC interfaces)
+
12V (+) (output v12V for control panels and PC
interfaces)
12V > 3 screw terminal block: ADC12
+
12V (+Battery)
-
0V (Input power supply 0V ADC12)
+
+ 12V (Input power supply ADC12)
BAT > 3 screw terminal block : Battery 7A – 12V
+
B
Not used
-
Battery -
CONTROL PANEL BOARD
5 screw terminal block: RS485
Blocks
Description
A
A (RS485 bus)
B
B (RS485 bus)
M
M (RS485 cable shielding)
-12V
-0V (power supply)
+12V
12V (+) (power supply)
*Refer to traffic light indicator manual