QUICK START
INSTALLATION GUIDE
w w w . c d v i g r o u p . c o m
Here are the LED status when connected to an
A22K ATRIUM controller :
Note:
Door output timings such as; unlock time (access granted),
door open too long pre-alarm and door open too long
alarm, can be modified in the ATRIUM software “Door
Properties” window.
LED State
Buzzer
Description
Steady blue
-
Standby (door se-
cure)
Green 5 sec.
Chirp beep Access granted
Red blinks
Steady
beep for
3 sec.
Access denied
Flashing blue
-
Reader compromised
(lost its encryption
key)
Blinks green every
3 sec.
-
Door unlock schedule
Flashing Red
Steady
beep
Door forced alarm
Flashing Red
Beep every
2 sec.
Door open too long
pre-alarm
Flashing Red rapidly
Fast beep Door open too long
alarm
It is recommended to use
CAT5e/6
cable
Distance between the reader and the controller up to
1220m (AWG 22 cable).
WIRING DIAGRAM
LED STATUS INDICATORS
MOUNTING
EXIT READER OPTION (RS485
ONLY):
Each A22K controller supports the
Input/Output reader, 2 readers per
door. Connect the 2 readers in parallel
(as shown below).
CAUTION
The dipswitch must be at the bottom
near the motherboard:
Set the position of the switch before
powering the player, or unplug and
plug the player if you change the dip
switch to the exit mode.
The 2 players must be separated
by a distance of 20 cm to avoid any
interference.
All
the
information
contained
within
this
document
(pictures,
dr
awing,
fea
tures,
specifications
and
dimensions) could be
perceptibly
diff
erent and can be changed
without
prior notice. CD
VI
_K3_QS_
01_FR
-EN_A4
_B
-
G0801FR0003V0
1
UP
Position the switch to the left
next to the terminal block
(manufacturer setting)
Position the switch
to the right
CDVI SAS
31 avenue du Général Leclerc
93500 PANTIN
01 48 91 01 02
135
80
22,6
Weight (g) :
Vol. (mm
3
) :
Project :
K3
C.A. :
Surface condition: Ra 3,2
General tolerance: 0.2
Material : ...
DES: W.Sainvil
A3H
SCALE 1:1
Date 14/04/2020
Edition 00
Plan M ...
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax : 33(0)148912121
www.cdvi.com
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
K3 READER
READER 1
READER 2
D1 / B-
RED1
GRN 1
BUZ 1
D0
/ A+
12V
D1 / B-
RED 2
GND
GND
GND
GND
GND
GRN 2
BUZ 2
D0
/ A+
12V
+12V DC
+24V DC
-
+12V DC
-
+12V DC
A+
B-
C 1
NO 1
NC 1
LK 1+
LK 1
-
LK 2
-
C 2
NO 2
NC 2
LK 2+
C 1
REX 1
12V
C 2
REX 2
12V
TMP
Input 1
Input 2
Output 1
Output 2
INPUT
POWER
SUPPLY
RS485
LOC
AL
BUS
ETHERNE
T
PORT
SYSTEM ST
ATUS
EXTR
A
INPUTS/
OUTPUTS
A22K CONTR
OLLER
READER PORT DOOR 1
A22K CONTR
OLLER
READER PORT DOOR 2
DOOR 1
DOOR 2
ETHERNE
T
LOC
AL BUS
LOCK 1 & 2
JUMPER SETTING
STATUS
24V DC INPUT/
BATTER
Y/
MODULE TYPE
BATTER
Y
BACKUP
ENCLOSURE
TAMPER
SWITCH
INPUT
INPUTS
DOOR 1
DOOR 2
LOCKS
D1 / B- (RS485 BUS)
D0 / A+ (RS485 BUS)
GND
12V DC
A22K CONTROLLER
ENTRANCE READER
EXIT READER