background image

QUICK START

INSTALLATION GUIDE

w w w . c d v i g r o u p . c o m

Here are the LED status when connected to an

A22K ATRIUM controller :

Note:

Door output timings such as; unlock time (access granted), 

door open too long pre-alarm and door open too long 

alarm, can be modified in the ATRIUM software “Door 

Properties” window.

LED State

Buzzer

Description

Steady blue

-

Standby (door se-

cure)

Green 5 sec.

Chirp beep Access granted

Red blinks

Steady 

beep for

3 sec.

Access denied

Flashing blue

-

Reader compromised 

(lost its encryption 

key)

Blinks green every

3 sec. 

-

Door unlock schedule

Flashing Red

Steady 

beep

Door forced alarm

Flashing Red

Beep every 

2 sec.

Door open too long 

pre-alarm

Flashing Red rapidly

Fast beep Door open too long 

alarm

It is recommended to use 

CAT5e/6

 cable

Distance between the reader and the controller up to 

1220m (AWG 22 cable).

WIRING DIAGRAM

LED STATUS INDICATORS

MOUNTING

EXIT READER OPTION (RS485 

ONLY):

Each A22K controller supports the 

Input/Output reader, 2 readers per 

door. Connect the 2 readers in parallel 

(as shown below).

CAUTION

The dipswitch must be at the bottom 

near the motherboard:

Set the position of the switch before 

powering the player, or unplug and 

plug the player if you change the dip 

switch to the exit mode.

The 2 players must be separated 

by a distance of 20 cm to avoid any 

interference.

All

 the

 information

 contained

 within

 this

 document

 (pictures,

 dr

awing,

 fea

tures,

 specifications

 and

  

dimensions) could be 

perceptibly 

diff

erent and can be changed 

without 

prior notice. CD

VI

_K3_QS_

01_FR

-EN_A4

_B

 - 

G0801FR0003V0

1

UP

Position the switch to the left  

next to the terminal block 

(manufacturer setting)

Position the switch 

to the right

CDVI SAS

31 avenue du Général Leclerc

93500 PANTIN

01 48 91 01 02

135

80

22,6

Weight (g) : 

Vol. (mm

3

) : 

Project : 

K3

C.A. : 

Surface condition: Ra 3,2

General tolerance:   0.2

Material : ...

DES: W.Sainvil

A3H

SCALE 1:1

Date 14/04/2020

Edition 00

Plan M ...

31, av du Gal Leclerc

93691 PANTIN CEDEX

F  R  A  N  C  E

Tel : 33(0)148910102

Fax : 33(0)148912121

www.cdvi.com

Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.

This document is the exclusive property of CDVI and it may not be disclosed to others without permission.

K3 READER

READER 1

READER 2

D1 / B-

RED1

GRN 1

BUZ 1

D0 
/ A+

12V

D1 / B-

RED 2

GND

GND

GND

GND

GND

GRN 2

BUZ 2

D0 
/ A+

12V 

+12V DC

+24V DC

-

+12V DC

-

+12V DC

A+

B-

C 1

NO 1

NC 1

LK 1+

LK 1
-

LK 2
-

C 2

NO 2

NC 2

LK 2+

C 1

REX 1

12V

C 2  

REX 2

12V

TMP

Input 1

Input 2

Output 1

Output 2

INPUT

POWER

SUPPLY

RS485

LOC

AL

BUS

ETHERNE

T

PORT

SYSTEM ST

ATUS

EXTR

A

INPUTS/

OUTPUTS

A22K CONTR

OLLER

READER PORT DOOR 1

A22K CONTR

OLLER

READER PORT DOOR 2

DOOR 1

DOOR 2

ETHERNE

T

LOC

AL BUS

LOCK 1 & 2

JUMPER SETTING

STATUS

24V DC INPUT/

BATTER

Y/

MODULE TYPE

BATTER

Y

BACKUP

ENCLOSURE

TAMPER

SWITCH

INPUT

INPUTS

DOOR 1

DOOR 2

LOCKS

D1 / B- (RS485 BUS)

D0 / A+ (RS485 BUS)

GND

12V DC

 A22K CONTROLLER

ENTRANCE READER

EXIT READER