EN
EN
DWAA
DWSR/ DWP Articulated Arm
4
B = 300 mm
Distance
Motor Axis -
Door
(thickness of
the wall)
Door hinge -
Door bracket
distance
Length of the
adjustable
arm
Max opening
angle of the
door
L1
A
H
C
60
580
490
110
90
660
550
100
120
580
530
110
150
580
555
113
180
580
580
108
210
540
590
117
240
540
600
110
B = 330 mm
Distance
Motor axis -
Door
(thickness of
the wall)
Door hinge -
Door bracket
distance
Length of the
adjustable
arm
Max opening
angle of the
door
L1
A
H
C
60
500
430
110
90
500
450
110
120
500
480
113
150
500
480
113
180
540
525
107
210
540
575
107
240
500
590
115
The following tables show the recommended mounting dimensions for the DIGIWAY
Plus and DIGIWAY SR referencing to B, L1, H and C shown in the previous diagrams.
B = 270 mm
Distance
Motor Axis -
Door
(thickness of
the wall)
Door hinge -
Door bracket
distance
Length of the
adjustable
arm
Max opening
angle of the
door
L1
A
H
C
60
660
550
115
90
660
570
110
120
580
550
120
150
620
590
110
180
580
595
118
210
500
580
140
L1
D1