PROFIL100EC
Illuminated Mullion Weatherproof Keypad
EN
INSTALLATION MANUAL
6
cdvi.se
cdvigroup.com
C. Changing the master code
The master code is used only
to enter in programming mode.
1. Enter the master code twice.
(
1 2 3 4 5
default value master code).
2 beeps are emitted to confirm
entry in programming mode.
2. Press A5 to modify the master code.
- One beep is emitted.
- Enter the new 4 or 5 digits master code.
- One beep is emitted to confirm
that the master code is programmed.
3. Press B to exit
from the programming mode.
2 beeps are emitted to confirm that
the keypad is in stand-by operating mode.
D.
Adding, changing
or deleting a user code
Group 1: From address 00 to address 99,
relay output 1
1. Enter the master code twice
(
1 2 3 4 5
default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. To add a user code, enter the user
location (from 00 to 99).
If the user location is used 4 beeps
are emitted, enter the 4 or 5-digits
User code.
3. To Change a User code enter
the user location.
-
4 beeps are emitted to indicate that
the user location is already programmed.
- Enter a new 4 or 5-digits code.
- A beep is emitted to confirm the new
user code.
4. To delete a User code enter
the user location.
-
4 beeps are emitted.
- Press
0 0 0 0 0
in 5-digits length code
or
0 0 0 0
in 4-digits length code.
- A beep is emitted to confirm the user
code has been deleted.
Note:
If the Pin code is already programmed or is
identical to the master code, then 4 beeps are
emitted. Press B to exit from the programming
mode. 2 beeps are emitted to confirm that the
keypad is in stand-by operating mode.
E. Time outputs
This section allows to program
the illumination time and the Relay
activation time.
1. Enter the master code twice
(
1 2 3 4 5
default value master code).
2 beeps are emitted to confirm
entry in programming mode.
2. Press A0 to program the key-in
keypad time and the keys lit time.
1 beep is emitted.
-
Enter the time in 10th of second –
10
for
10 seconds up to
99
for 99 seconds
The backlighting dims 10 seconds after
the last keypress or switches off after
entering a valid code.
- Press
00
for permanent illumination keys.
- One beep is emitted to validate the time.
3. Press A1 to program relay 1
output time (door release time).
-
1 beep is emitted.
- For a latched output enter the time
in seconds –
01
for 1 second up to
99
for 99 seconds.
- Press
00
for a toggled output.
- One beep is emitted to validate the time.
4. Press B to exit from
programming mode.
2 beeps are emitted to confirm that
the keypad is in stand-by operating mode.
4 beeps indicate a data computing error.