Connecting Electric Lock
Door Lock Controlled with Internal Power
Door Lock Controlled with Dry Contact
3.The jumper should be placed on position
2 and 3 before connecting.
1.The external power supply must be used
•
Power-on-to-unlock type:Unlock
Mode=0 (by default)
•
Power-off-to-unlock type:Unlock
Mode=1
EB
*
LOCK
Jumper position on 2&3
1 2 3
L1 L2 PL S+ S-
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER
SUPPLY
WIRING
1.Electronic lock of Power-on-to-unlock
(fail Secure)
type should be used.
4.The door lock control is not timed from
Exit Button(EB).
2.The door lock is limited to 12V, and hold-
ing current must be less than 250mA.
according to the lock
requirements
.
2.The in
ternal
relay contact is restricted
to 230Vac 1A or 24Vdc 1A.
3.The jumper must be taken off before
connecting.
*
CDV
-RLC relay actuator is
required
for 2nd lock connection.
5.The
Unlock Mode
is
set to 0 (by
default).
4.Set the
Unlock Mode
according to
different lock types.