background image

-19-

 Basic IN-OUT  Wiring in Standard Mode

Connecting Multi Monitors

WIRING

ID=0

Code=1, DIP6=off

Optional functional module

SCU

 camera module(max.4)

GSM

 module(mobile phone transfer)

TPS

 module(PBX transfer)

QSW

 image quad splitter module

(Master)

Code=1, DIP6=off

(Slave 2)

Code=1, DIP6=on

(Slave 3)

BUS(IM) BUS(DS)

PC6A

AC~

100~240VAC

Code=1, DIP6=off

(Slave 1)

RF CARD

SCU

GSM

TPS

QSW

• 

Please set door station 

to

 group calling 

mode if there 

are

 more than 4 monitors 

on the system 

(Refer to Page 9)

• 

Distributor

 (CDV-DBC4A)

 is 

not 

required for a 

full audio system, 

daisy 

chain connection is the recommended. 
wiring format.

•  

T

he  last  monitor  connected

 in  this 

format

,  should set to 

ON

•  

The  door  statio

n  

i

s  

compatible  with  

all

monitors

within the CDVI 2Easy range.

Содержание CD97-4ID

Страница 1: ...al carefully to ensure safe and correct operation Keep this manual well for future reference RF CARD RF CARD 2 WIRE SYSTEM CDV97 Series Fisheye Camera Door Station With Proximity Access Control CD97 4...

Страница 2: ...de 8 Setting Camera Resolution 10 Setting Unlock Mode 10 Setting Unlock Time 11 Setting Nameplate Illumination Mode 11 Setting Night View LED Illumination Mode 12 Setting Ring back Tone 12 Setting Ima...

Страница 3: ...10 9 1 3 4 8 7 6 5 12 13 2 1 Microphone 2 UNLOCK indicator 3 CALL indicator 4 Call button 5 Nameplate 6 Front panel 7 Speaker 8 Night view LED 9 Camera lens 10 Rain cover 11 Mounting hook 12 Connectio...

Страница 4: ...than 1700 Rain cover Main Unit 1 2 3 4 5 The distance between the top of main unit and rain cover should be not less than 3mm Main unit Rain cover 1 Drill holes in the wall to match the size of wall...

Страница 5: ...R Motion Detector Connect Port 12V GND PIR L1 L2 PL S S Main Connect Port Motion Detector Connection Port To connect external PIR motion detector PL External lock power input connect to the PSU positi...

Страница 6: ...or lights up a single beep will be heard and the lock relay will activate If an unauthorised user card tag is presented three beeps will be heard and the lock relay will NOT activate Please note that...

Страница 7: ...D Zoom mode Full screen mode Alternate switching mode This section explains the settings of each function please refer to the table below Each operation is indicated by the LED indicator and the buzze...

Страница 8: ...Beep Beep Beep ID 0 1st door station ID 1 2nd door station ID 2 3rd door station ID 3 4th door station PROGRAMMING INSTRUCTIONS A total of 4 addresses can be configured Addresses can be modified eithe...

Страница 9: ...address 01 by default Call button B calls the monitor with address 02 by default Call button C calls the monitor with address 03 by default Call button D calls the monitor with address 04 by default C...

Страница 10: ...tion of the camera can be changed at any time between high or low resolution High resolution is the default setting to change the setting please follow the steps below If still in programming mode the...

Страница 11: ...ameplate illumination mode to Auto Press KEY_3 By default the unlock time is 1 second the time setting range is 1 99 seconds To change the unlock time follow the steps below There are 3 illumination m...

Страница 12: ...gain to close ring back call tone Press KEY_1 There are 3 working modes for the night view LED Normally on Normally off and Auto Auto is the default setting to change this setting please follow the st...

Страница 13: ...econds then switch to Zoom image When answering a call When the door station calls a monitor the camera image will be displayed on screen there are 3 modes for the displayed image Alternate switching...

Страница 14: ...use Proximity card frequency 125kHz Full screen mode When answering the call the image will be displayed on Zoom mode for 5 seconds then switching to Full screen as a reminder to enter talking status...

Страница 15: ...CARD DELETE UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep UNLOCK Indicator Blink one time TALK Indicator OFF Buzzer Beep Press KEY_2 button After powering on within 10s press and hold on K...

Страница 16: ...ETE to ID card window in standby Show the MASTER CARD ADD to ID card window Show the MASTER CARD ADD again format is activated Show the MASTER CARD DELETE to ID card window in standby Show user cards...

Страница 17: ...position 2 and 3 before connecting the lock 4 NOTE The door lock control is not timed from Exit Button EB 5 The Unlock Mode must be set to 0 default 1 An external power supply must be used in accordan...

Страница 18: ...oor station ID 3 4th door station L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S To monitors RF CARD RF CARD RF CARD RF CARD A maximum of 4 door stations can be connected to the system Please ens...

Страница 19: ...de 1 DIP6 on Slave 3 BUS IM BUS DS PC6A AC 100 240VAC Code 1 DIP6 off Slave 1 RF CARD SCU GSM TPS QSW Please set door station to group calling mode if there are more than 4 monitors on the system Refe...

Страница 20: ...onal functional module BDU Star Topology Wiring With DBC4A1 in Standard Mode BDU Bus amplifier module RLC Relay Lock module DBC4A1 Branch distributor The door station is compatible with all monitors w...

Страница 21: ...er or diluted soap and water to clean off dirt The unit is weather resistant However do not use high pressure water cleaners on the door panel directly Excessive moisture may cause problems with the u...

Страница 22: ...limited in the DT system Using different cables may also affect the maximum distance which the system can reach Cable and distance unit m Cable Usage A B 2 IM B 16 IM Twisted cable 2x0 75mm2 60 100 40...

Страница 23: ...23 B A C 2 2 DBC4A1 RF CARD PC6A Cable and distance unit m Cable Usage A B C Twisted cable 2x0 75mm2 60 60 30 Twisted cable 2x1mm2 80 80 40 APPENDIX Star Topology Wiring Mode With DBC4A1...

Страница 24: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved DT ENG DT607 V1...

Отзывы: