background image

8

cdvigroup.com

9

cdvigroup.com

7] LED MANAGEMENT ON CENTAUR SYSTEM

GREEN LED

SETTINGS

RED LED 

SETTINGS

GREEN

 ACCESS ALLOWED

RED

 ACCESS DENIED

BLUE

 STAND-BY

LED

ACTUATION

8] NOTES

  Wiegand 26, 30 ou 44 bits.

   Connexion directe à la centrale ou via  

le contrôleur de porte (INTBUSW).

   Electronique  résinée.

  Signalisation lumineuse et sonore.

  45 cm de câble (STARPW-STARPB).

   Disponible en version : blanc, gris ou noir.

  SOLARPW-SOLARPB (L x l x P) : 130 x 90 x 28 mm.

  STARPW-STARPB (L x l x P) : 130 x 41 x 28 mm.

  Technologie : 125 Khz. 

  Protocole : lecteur multi-carte - Marin/HD.

   Alimentation : 12 V DC.

  Consommation : 100 mA.

1] PRÉSENTATION PRODUIT

3] ÉLEMENTS FOURNIS

2] RAPPELS ET RECOMMANDATIONS

Joint  

d’étanchéité

Joint  

d’étanchéité

Vis TF  

3x30

Cheville  

plastique  

S5

Embout  

tournevis  

TORX

®

Vis TORX

®

  

3x8

Varistance

SOLARPW(PB)

1

-

2

2

1

1

1

STARPW(PB)

-

1

2

2

1

1

1

Recommandations  

d’installation

Pour sécuriser l’installation, 

n’oubliez pas de placer la 

varistance sur le système 

de verrouillage en parallèle 

au niveau de l’alimentation. 

Câble préconisés

Câble 4 paires 6/10

ème

 (AWG 24). 

Alimentations  

préconisées

 

ARD12 et BS60 (lorsque le 

lecteur n’est alimenté ni par 

la centrale, ni par le contrô-

leur de porte [INTBUSW]).

Environnement

Si vous installez ces lecteurs 

dans un environnement  

marin/salin,il est préconisé  

de passer du vernis en 

bombe sur les contacts 

après câblage afin de préve

-

nir le risque d’oxydation.

Ce produit est livré  

avec une varistance. 

Celle-ci doit être montée 

directement sur les bornes de 

la gâche (ventouse, moteur,…) 

commandée par l’équipement. 

Si l’appareil fonctionne avec 

plusieurs gâches, chacune doit 

être équipée de varistance. 

La varistance limite les sur-

tensions provoquées par le 

bobinage de la gâche – effet de 

self. Dans le cas où la ventouse  

utilisée est du type “Shear Lock”, 

celle-ci doit être alimentée par 

une alimentation indépendante 

du SOLARPW-SOLARPB ou du 

STARPW-STARPB. 

Réf :

 SOLARPW-SOLARPB

Réf :

 STARPW-STARPB

Pour un 

éclairage 

optimal, 

attention de 

ne pas plier  

le câble à 

l’intérieur 

du produit.

Certification CE

Certification FCC CFR 47

part 15 compliance

DEEE

IP53

-25°C à +70°C

EN

SOLARPW-SOLARPB-STARPW-STARPB

Wiegand 125Khz Proximity Readers 

  INSTALLATION MANUAL

FR

SOLARPW-SOLARPB-STARPW-STARPB

Lecteurs Proximité Wiegand 125 Khz

  INSTALLATION MANUAL

Содержание 3662211001466

Страница 1: ...The installer s choice cdvigroup com SOLARPW SOLARPB STARPW STARPB SOLARPW STARPW SOLARPB STARPB Wiegand 125Khz Proximity Readers Lecteurs proximité Wiegand 125 Khz ENGLISH EN FRANCAIS FR ...

Страница 2: ...varistor The varistor limits overload produced by the strike coil known as self effect or back emf If you are using a Shear Lock elec tromagnet or other type of electric lock we recommend the use of a dedicated power supply for the lock For optimal illumination do not fold the cable inside the product CE Certification Certification FCC CFR 47 part 15 compliance WEEE IP53 25 C to 70 C Ref SOLARPW S...

Страница 3: ...H Clock D0 Data 0 D1 Data 1 B Buzzer V Green LED R Red LED SOLARPW SOLARPB C56 C58 C61 1 MM10 4 3 2 1 ON ON ON ON L7 Q6 Q7 Q8 R77 R78 R79 P1 1 P3 BZ3 C6 C24 C59 MM1 MM14 CR3 CR10 CR25 CR26 CR24 MM3 MM15 CR12 CR13 CR15 I1 MM16 CR22 P2 CR19 CR21 CR20 CR28 CR27 CR29 CR11 R70 R67 R68 R64 R69 R65 C68 CR30 Cable Red Input voltage 12V dc Black 0V Blue Clock Green Data 0 White Data 1 Brown Buzzer input Ye...

Страница 4: ...he first 14 bit Code A code is formed from 7 half byte Each byte is transferred from bit 7 to bit 0 2 Second parity odd parity for the last 14 bit Bit 1 Bit 2 to bit 29 Bit 30 Even Parity from bit 2 to bit 15 Data 28 bit Odd Parity from bit 16 to bit 29 Exemple A Temic card decimal code 689905 in hexadecimal A86F1 1 0000 0000 1010 0110 0110 1111 0001 0 Parity 1 0 0 A 8 6 F 1 Parity 2 The code numb...

Страница 5: ...ires 6 10ème AWG 24 Alimentations préconisées ARD12 et BS60 lorsque le lecteur n est alimenté ni par la centrale ni par le contrô leur de porte INTBUSW Environnement Si vous installez ces lecteurs dans un environnement marin salin il est préconisé de passer du vernis en bombe sur les contacts après câblage afin de préve nir le risque d oxydation Ce produit est livré avec une varistance Celle ci do...

Страница 6: ...c la vis TORX grâce à l outil TORX fig c N oubliez pas de placer la varistance au niveau du système de verrouillage Voir page 2 Rappels et recommandations Joint d étanchéité FR FR SOLARPW SOLARPB STARPW STARPB Lecteurs Proximité Wiegand 125 Khz SOLARPW SOLARPB STARPW STARPB Lecteurs Proximité Wiegand 125 Khz INSTALLATION MANUAL INSTALLATION MANUAL 1 A l aide du fond du lecteur prenez les marques p...

Страница 7: ...2 1 ON ON ON ON L7 Q6 Q7 Q8 R77 R78 R79 P1 1 P3 BZ3 C6 C24 C59 MM1 MM14 CR3 CR10 CR25 CR26 CR24 MM3 MM15 CR12 CR13 CR15 I1 MM16 CR22 P2 CR19 CR21 CR20 CR28 CR27 CR29 CR11 R70 R67 R68 R64 R69 R65 C68 CR30 4 1 ON 4 1 ON Positionnement Dipswitch 1 2 Positionnement Dipswitch 3 Positionnement Dipswitch 4 6 FORMAT DE SORTIE WIEGAND 26 30 ET 44 BITS Chronogrammes Sorties en collecteur ouvert avec pulls u...

Страница 8: ...t 15 est pair 1 si le nombre de 1 dans bit 2 à bit 15 est impair Parité 2 0 si le nombre de 1 dans bit 16 à bit 29 est impair 1 si le nombre de 1 dans bit 16 à bit 29 est pair Format Wiegand 44 bits Format 44 bits hexadécimal La communication s effectue par une liaison de type Wiegand 44 bits Signaux DATA1 DATA0 et CLOCK La trame est constituée d une totalité de 44 bits et se décompose comme suit ...

Страница 9: ... 48 91 21 21 CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 84606132 82 Fax 86 0 10 84606...

Отзывы: