background image

 

 

 

 
 
1.

 

Description 

 

The  Blow  &  Go  coin-operated  Alcohol  Breath  Tester  is  designed  to  measure  your 
alcohol  concentration  level.  With  an  advanced  fuel-cell  sensor,  this  device  offer 

high  sensitivity  and  is  extremely  accurate.  Its  easy  testing  process  and  complete 
functions make  it versatile.  When  your  alcohol blood  content  exceeds  the  preset 
alarm level, it will send an alarm warning and show the result directly and clearly on 

the LCD digital display.  

 

2. 

Main Technical Data 

 

 

Model 

Blow & Go 

Sensor type 

Fuel cell sensor 

Working Voltage 

AC110V

AC220V, 50/60HZ 

Working Current 

≤15mA 

Environment 

Temperature

-10ºC

50ºC

Relative humidity

≤95% 

No Dews 

Response Time 

< 8s 

Test Range 

 

0.000

2.000mg/L

0

440mg/100mL, 0.000

4.000g/L,  

0.000

0.400%BAC, 0.000

2.000‰BAC

 

Warning level 

Warning level

0.090mg/L

Danger level

 0.250mg/L 

Accuracy 

±0.005% at 0.05%BAC 

Warning method 

Audio and light 

Display 

 

Four digits LCD display. Test process and result are 

shown with red, green, and yellow indicator lights 

Dimension 

lxwxh,mm:250×105×400 

Indication manner 

mg/l, mg/100ml, g/l, %BAC, ‰BAC optional 

Coin for single time 

0 —— 15 (For 0, the unit can be tested without a coin) 

Coin diameter 

20mm – 28mm 

Coin Thickness 

1.2mm – 2.5mm 

Coin capacity 

200 units 

Straw capacity 

200 units

(¢

≤7mm) 

 

 
 

C.D.Products S.A

Содержание Blow & Go 4500

Страница 1: ...1 Blow Go CDP 4500 Coin operated Alcohol Breath Tester C D P r o d u c t s S A...

Страница 2: ...AC110V AC220V 50 60HZ Working Current 15mA Environment Temperature 10 C 50 C Relative humidity 95 No Dews Response Time 8s Test Range 0 000 2 000mg L 0 440mg 100mL 0 000 4 000g L 0 000 0 400 BAC 0 00...

Страница 3: ...n the front panel The test unit is set by the first second and third switches This means that the switch on the top is 1 and the switch on the bottom is 0 Note switch number 4 is not used and an X wil...

Страница 4: ...in Photo 3 both the first and third switches are at the bottom they both mean 0 the second and fourth switches are at the top they both mean 1 So according to Table 2 in this example you would need 5...

Страница 5: ...e insert coin slot we recommend inserting coins of different years and versions do this both quickly and slowly to imitate the normal way users would do it When you have finished the Light indicator w...

Страница 6: ...the tester continuously and don t stop until you hear the prompt tone If you stop blowing during the test the device will emit a di di di sound and will inform that the blowing is incomplete You shoul...

Страница 7: ...rew the knob in a clockwise direction and then connect the small tube and the white connector It s now ready for use Photo 8 10 Recommendations Avoid dropping or hitting the unit Very Important To avo...

Страница 8: ...ircuit fault Contact distributor No response to Warm up has not concluded Wait until the warm up gas detection concludes Circuit fault Contact distributor 12 Contact data C D Products S A Pol gono P 2...

Отзывы: