background image

 

CDP 7000 

FAST SCREENING 

ALCOHOL TESTER 

 

OPERATION MANUAL 

 

 

 

 

PLEASE READ THIS MANUAL CAREFULLY BEFORE 

USING THE TESTER

 

 

 

 

 

 

Content 

Catalogue 

 

C.D.Products S.A.

Содержание 7000

Страница 1: ...CDP 7000 FAST SCREENING ALCOHOL TESTER OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE TESTER Content Catalogue C D P r o d u c t s S A ...

Страница 2: ...OWER OFF 3 4 2 1 Manual power off 3 4 2 2 Power saving 3 4 2 3 Low battery 3 5 TESTING 4 6 SETUP 5 6 1 Calibration reminder 6 6 2 Date setup 6 6 3 Measurement unit setup 6 6 4 Blowing time 6 6 5 Test result display time 7 7 TROUBLESHOOTING 8 8 MAIN TECHINCAL INDEXES AND PARAMETERS 8 9 MAINTENANCE 9 C D P r o d u c t s S A ...

Страница 3: ...This breath tester is ideal to carry out alcohol level tests at the start of the day or to help prevent accidents and encourage safe driving conditions Main features Adopts advanced 16 bit low power consumption Fuel cell sensor high reliability and accuracy Color easy read LCD indication Light indication function matrix type warning lamp Simple keyboard operation Shows real time temperature and da...

Страница 4: ...2 3 STRUCTURE 3 1 Appearance Fig 1 3 2 Display Fig 2 1 Blowing nozzle 4 Sling 7 Head lamp 2 Screen 5 USB Port reserved 8 Alarm lamp 3 Keyboard 6 Battery cover C D P r o d u c t s S A ...

Страница 5: ... will flash Press the left button again and the lamp will turn off Important The red and green lights will only flash when the main menu is in testing mode They can also be used as additional lights if their use is required 4 2 Power off 4 2 1 Manual power off To turn off the unit press and hold the button for 3 seconds 4 2 2 Power saving This breath tester includes a power saving function If the ...

Страница 6: ...e alarm level set before the test procedure If the result is normal the green light will also flash 2 Drink If the drinking message appears above the concentration value it means that the test result is above the alarm level set before the test procedure If this happens the breathalyzer will emit an acoustic alarm and the red light will flash 3 Passive testing If the person that should carry out t...

Страница 7: ... test results will be displayed on the screen before automatically returning to the test menu to continue performing controls If the person that takes the test is appears very drunk we recommend that you allow clean air into the blowing tube in order to eliminate possible residuals from previous alcohol tests allowing more precise subsequent tests 6 SETUP In the main menu press the right button to...

Страница 8: ...he measurement unit setup menu press the left button to choose the unit and then press the right button to save the settings Press the button to exit the menu The new measurement unit will be automatically saved when you exit this menu if a change has been made After changing the unit the alcohol concentration alarm levels will be automatically updated and the conversion will also be done automati...

Страница 9: ...he test mode Press the left button to select how long you want the result displayed Press the right button to save the change Press after setting the value to exit the display time menu If the value has been changed it will be automatically saved when you exit the menu The save interface will appear as a reminder 7 TROUBLESHOOTING Table 2 Fault Description Possible Reason Solutions Unable to turn ...

Страница 10: ...his menu 8 MAIN TECHNICAL INDEXES AND PARAMETERS Table 3 Model CDP 7000 Sensor type Fuel cell alcohol sensor Measurement range 0 2 000mg L 0 440mg 100ml Warm up time Warm up not necessary Response time 1s Continuous working time 100 2000 times depends on battery capacity Dimensions L W H 284 68 5 74mm Net weight About 400g with 4 batteries Recommended calibration periods 6 12 months 9 CARE AND MAI...

Страница 11: ...ndicates a level of alcohol below 0 25 Mg L in air 2 If you drive or operate machinery after drinking alcohol you do so at your own risk There are no express or implicit guarantees in relation to the use of the device 3 Liability is only limited to the cost of the unit The warranty has a duration of 6 months from the unit s date of purchase with regard to any manufacturing defects If you require t...

Страница 12: ...0 CONTACT DATA C D Products S A Polígono Industrial P 29 28400 Collado Villalba Madrid www cdpsa es Customer service hotline 902 10 40 60 Email clientes cdpsa es Fax 91 851 71 60 C D P r o d u c t s S A ...

Отзывы: