9
2
.
OVERLOAD INDICATOR LIGHT
The overload indicator light flickers when an overload of a connected
electrical device is detected. This situation shall not be kept for a long
time and it just needs to decrease the loads to its normal range and
the overload indicator light will go off.
When the load is detected to exceed the maximum power or the AC
output voltage is reduced, the overload indicator light will come on
and the electronic breaker will then activate, stopping power to the
generation in order to protect the generator and any connected
electric devices. The output pilot light (Green) will be off, the overload
indicator light will turn RED. It is needed to process as follows,
(a)
Turn off any connected electric devices
(b)
Reduce the total wattage of connected electric.
(c)
Check for blockages in the cooling air inlet, muffler air
exhaust pipe opening and the control unit.
(d) After inspection, press the reset button to restore the power
supply of the generator.
CAUTION:
⚫
The generator AC output automatically resets when the engine is stopped and then restarted.
⚫
The overload indicator light may come on for a few seconds at first when using electric devices that require a large
starting current, such as a compressor or a submergible pump. However, this is not a malfunction.
3. DC APPLICATION (option)
This usage is applicable to 12V battery charging only.
(a)
Charging instruction for battery
⚫
Disconnect the leads for the battery.
⚫
Make the battery fluid filler cap loose fully.
⚫
Fill distilled water to the upper limit, if the battery fluid is low level.
⚫
Measure the specific gravity for the battery fluid by using the
hydrometer, and calculate the charging time in according with the
table shown on right side.
⚫
The specific gravity for the fully charged battery shall be within 1.26
to 1.28. It is recommended to confirm every an hour.
3
2
1
C
Speci
fic grav
ity 20
¡ã
3. 47AH 20HR
2. 35AH 20HR
1. 30AH 20HR
Battery capacity
chargong time Hr
8
10
4
6
2
0
1.06
1.14
1.10
1.22
1.18
1.26
1.30
Aim for specific gravity and charging time
RESET