6
. PROGRAMMABLE PARAMETERS TABLE
Here below is a description of all the parameters available on the instrument. Some of them may not be present, either due
to the fact they depend on the type of instrument or because they are automatically disabled as unnecessary.
Parameter
Description
Range
Default
Note
1
S.Lt1 s.t1
min. Set time
0 ÷ S.Ht1
0
2
S.Ht1 s.t1
max. Set time
S.Lt1 ÷ 9999
99.59
3
S.Lt2 s.t2
min. Set time
0 ÷ S.Ht2
0.00
4
S.Ht2 s.t2
max. Set time
S.Lt2 ÷ 9999
99.59
5
S.St1 s.t1
Time range
1 Hours (9999 h);
2 Hours - Minutes (99 h 59 min);
3 Minutes - Seconds (99 min 59 s);
4 Seconds - Hundreds of seconf (99 s 99 1/100 s).
3
6
S.St2 s.t2
Time range
3
7
S.t1
s.t1
Set time
S.Lt1 ÷ S.Ht1
0.00
8
S.t2
s.t2
Set time
S.Lt2 ÷ S.Ht2
0.00
9
S.t3
s.t3
Set time
S.Lt1 ÷ S.Ht1
0.00
10
i.Fct
CNT input
operating mode
1 Bistable START/STOP;
2 Bistable RESET-START/STOP;
3 Monostable START/STOP;
4 Monostable RESET-START/STOP;
5 Bistable RESET/START/STOP;
6 Bistable START/STOP-RESET.
2
11
F.o1t
OUT1 output
operating mode
1 On delay;
2 Feed-through;
3 Asymmetrical oscillator with start ON;
4 Asymmetrical oscillator with start OFF;
5 Asymmetrical oscillator with start ON (one cycle only).
1
12
F.o2t
OUT2 output
operating mode
oF No function;
1 Out2 operates as Out1;
2 Instantaneous Contact Output (ON during count);
3 Out2 operates as Out1 but with absolute Set time
s.t3
;
4 Out2 operates as Out1 but with relative Set time
s.t3
in advance;
5 Out2 operates as the buzzer.
oF
13
F.Cnt
Count
mode
uP UP;
dn DOWN.
uP
14
F.buF
Buzzer
operating mode
oF Disable;
1 Sounds at end of the cycle for the
s.t2
key pressure;
2 Sounds at end of the cycle for the
s.t2
period;
3 Key pressure sound only;
4 External buzzer only (if configured on Output 2 with
F.o2t
=
5
)
with end of the cycle for the
s.t2
period
1
15
t.UFt
-START/STOP
button operating
mode
oF No function
1 RESET only
2 RESET-START/STOP if
i.Fct
=
1
/
2
, or
RESET/START/STOP if
i.Fct
=
5
/
6
2
16
t.Edt
Times visibility with Fast Set time
procedure (
key)
oF No Set time visibility;
1
S.t1
;
2
S.t2
;
3
S.t1
and
S.t2
;
4
S.t3
;
5
S.t1
and
S.t3
;
6
S.t2
and
S.t3
;
7
S.t1
,
S.t2
and
S.t3
;
8
S.t1
only directly with
/
keys with no
key pressure.
1
17
F.but
Backup operation mode
1 Resets the current count;
2 Stops the current count storing the value reached;
3 Stores the reached value and when the power returns, it restarts
from that value if the conditions for restarting are present.
1
18
t.Lo
Keyboard lock
oF Lock disabled;
1 ÷ 9999 s
oF
19
t.PP
Password parameters protection
oF Password disabled;
1 ÷ 9999
oF
ELETTROMECCANICA CDC S.r.l - TX40
- MANUAL rev.2 - PAG.
9