20
Lubrication of the Gas Taps
The operations must be executed by a qualified technician.
IMPORTANT: All intervention regarding installation maintenance and conversion of the applian-
ce must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this obligation.
Table for the Choice of the Injectors
GB
Cat: II 2H3+
Burners
Nominal
Power
kW
Reduced
Power
kW
G30
- 28-30 mbar
G31
- 37 mbar
G20
- 20 mbar
Ø Injector
1/100 mm
Ø Injector
1/100 mm
Auxiliary (A)
1,00
0,30
50
72 (X)
Semi-Rapid (SR)
1,75
0,45
65
97 (Z)
Rapid (R)
3,00
0,75
85
115 (Y)
Triple Ring (TR)
3,50
1,50
95
135 (T)