23
CONNECTION TO THE GAS SUPPLY
✓
Be careful when flexible pipes are used that they do not come into contact with
moving parts.
✓
To maintain the thickness of 3 cm, the hob is fitted with a channel to contain the
connection pipe.
✓
The gas inlet union can be turned in the direction required after the elbow fitting
“
C
” and nut “
A
” connection (figure 17) has been slackened (Fig. 18).
✓
Never put it in the horizontal or vertical position.
✓
Never attempt to turn the elbow “
C
” without having first slackened off the relative
lock
nut
“
A
”.
✓
The gasket “
F
” (fig. 17) guarantees the seal of the gas connection.
It is recommended that it be replaced whenever it shows even the slightest
deformation or imperfection.
✓
Using a suitable leak detection fluid solution (e.g. Rocol) check each gas
connection one at a time by brushing the solution over the connection.
The presence of bubbles will indicate a leak. If there is a leak, tighten
the fitting and then recheck for leaks.
IMPORTANT! Do not use a naked flame to test for leaks
Figure 18
Figure 17
1/2" G co
n
ic
al
(ISO 7-1)
mal
e
1/2" G cy
l
i
ndr
ic
al
(ISO 22
8
-1)
mal
e
1/2" G cy
l
i
ndr
ic
al
(ISO 22
8
-1) fe
mal
e
C
F
A
GAS CONNECTOR
Cat: II 2H3+
The fitting (fig. 17) is made up of:
✓
1 nut “
A
”
✓
1 elbow fitting “
C
”
✓
gasket “
F
”
GB