Mounting the extractor
Once you are content with the prepared
area, drill out the fixing hole markings
using a Ø10mm bit suitable for the solid
ceiling. Remove the wingnut and two
washers from each mechanical anchor.
Place each anchor into the four Ø10mm
holes. Ensure the anchor end (A in Fig. 16)
is in the solid ceiling.
Using a 10mm spanner, fully tighten the nut highlighted by the arrow
in Fig. 16. This will splay the anchor within the drilled hole. Do this for
each anchor.
Once you are content that the anchors are solidly secured, raise the
extractor up to them and guide the pre-cut holes in the motor housing
over the threaded screws. Connect the ducting and either connect
or make free the electrical cable so that it can be connected to the
mains later.
Do not
yet switch the power to the extractor on.
Whilst those helping you are supporting the body of the extractor,
attach the washers and the wingnuts and tighten as far as they will go.
Ensure the extractor is securely fastened.
Refit the centre panel, the cover panel and the grease filters.