At the end of its working life, the product must be taken to a special 

local authority waste collection centre or to a dealer providing 

appliance recycling services.

Disposing of a household appliance separately avoids possible 

negative consequences for the environment and health. It also 

enables the constituent materials to be recovered, saving both energy 

and resources. As a reminder of the need to dispose of household 

appliances separately, the product is marked with a crossed-out 

wheeled dustbin.

Please note:

   Under no circumstances should the extractor be connected to any 

gas ventilation system, flue system or hot air ducting system.

 

Do not vent the extractor into an attic or loft space.

   Only house the extractor in rooms with adequate ventilation. 

Remember that the extractor is powerful and whatever air is 

extracted needs to be replaced.

   Do not tile the extractor in. It should be removable for service or 

maintenance.  

  Do not use silicone sealant to secure the hood to the wall.

   You must be able to isolate the extractor from the mains electrical 

supply after installation.

   This extractor has been designed to be used in a room with a 

volume of less than 36m .

  Steam cleaners must not be used when cleaning this appliance.

   The performance of your extractor will vary depending on a number 

of factors. These include: type of extraction, length of ducting, room 

volume, ventilation available and cleanliness of the filters.

Содержание ECHK90

Страница 1: ...www cda eu ECHK90 ECPK90 Extractors Installation use and maintenance Cod 0103083641 00 06...

Страница 2: ...notes 5 Using your extractor 6 Care and maintenance 7 Changing the charcoal filter 8 Mounting your extractor 9 Ducting 10 Installation 13 Mains electricity connection 14 Electrical information 14 Tro...

Страница 3: ...servicing or maintenance except by suitably qualified personnel Appliance information Please enter the details on the appliance rating plate below for reference to assist CDA Customer Care in the even...

Страница 4: ...stem or hot air ducting system Do not vent the extractor into an attic or loft space Only house the extractor in rooms with adequate ventilation Remember that the extractor is powerful and whatever ai...

Страница 5: ...end of cooking Control Panel A Power off button B Speed level buttons C Light button To switch the extractor light on or off Press button C To switch on the extractor or to change the speed at any tim...

Страница 6: ......

Страница 7: ...it completely fig 2 To replace the grease filter repeat the steps in reverse Please note Cleaning the grease filters in the dishwasher may lead to discolouration This is normal and does not constitut...

Страница 8: ...e top of the burners IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm Replaceable LED only light source by a profe...

Страница 9: ...fficient your extractor will be The lengths of ducting with minimal effect on performance are as follows 4 metres with 1 x 90 bend 3 metres with 2 x 90 bends 2 metres with 3 x 90 bends Longer ducting...

Страница 10: ...he property Installation steps 1 Firstly fix the vent outlet to the extractor body using four screws as shown in fig 5 2 Using the supplied template mark the positions of the ceiling mounting screws a...

Страница 11: ...of the chimney and ensure that it is equal or less than the height calculated in step 3 When the extractor is mounted the height between the hob and extractor must Fig 9 Fig 8 Fig 7 1 slide rail 2 top...

Страница 12: ...inally raise the inner section of the chimney to the ceiling and secure in place using the two small screws supplied 9 Note that the electrical connection to the extractor should not be located inside...

Страница 13: ...with the following code BLUE NEUTRAL BROWN LIVE GREEN YELLOW EARTH As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the termina...

Страница 14: ...and fused spur and is intended to be protected by a 3A fuse The use of a 13A fuse can cause damage to the internal wiring in the event of a fault and may also invalidate the warranty NOTE USE A 3A FU...

Страница 15: ...ed airflow at Best Efficiency Point QBEP 226 0 224 3 m3 h Measured Pressure at Best Efficiency Point PBEP 148 0 126 0 Pa Maximum airflow QMAX 404 4 387 4 m3 h Measured electric power at Best Efficienc...

Страница 16: ...9HY T 01949 862 012 F 01949 862 003 E customer care cda eu For service or queries relating to your product please contact The Customer Care Department on 01949 862 012 or email customer care cda eu Fo...

Отзывы: