Assembly and electrical connection should be carried out by
competent personnel.
When installing this product we recommend you seek the help of
another individual.
Do not mount the isolation switch behind the chimney section. It is a
requirement that you must be able to isolate the extractor from the
mains electrical supply after installation.
This appliance is intended to be connected to the mains electrical
supply by means of an isolation switch and fused spur and is intended
to be protected by a 3A fuse. The use of a 13A fuse can cause
damage to the internal wiring in the event of a fault, and may also
invalidate the warranty.
NOTE: USE A 3A FUSE
Electrical Information
Mains electrical voltage:
230 – 240Vac.
Total rated power consumption: ECHK90: 104W
ECPK90:
108W
Troubleshooting
If your extractor is not working:
1.
Check that the mains supply has not been switched off.
2.
Check that the fuse in the spur has not blown.